Smart EPD
Coxdome Shev (AOV) - RO16

Environmental Product Declaration

Coxdome Shev (AOV) - RO16

by VELUX

Environmental Product Declaration (EPD) for Coxdome Shev (AOV) - RO16, manufactured by VELUX. Declaration SmartEPD-2026-077-0894-01, prepared according to IBU Part B: Requirements on the EPD for Windows and Doors, valid until June 1, 2031.

Download the EPD (PDF)

Declared unit
1 m2 of product of a window ≤ 2,3 m² (reference dimensions according to EN 17213: 1,23 m × 1,48 m)
Valid until
June 1, 2031
PCR
Windows and Doors

Declaration details

Manufacturer
VELUX
Program operator
Smart EPD
Declaration number
SmartEPD-2026-077-0894-01
Date of issue
June 1, 2026
Valid until
June 1, 2031
Product category rules (PCR)
IBU Part B: Requirements on the EPD for Windows and Doors (version 1.0/1.7/1.4)
Standard
ISO 14025:2006 and EN 15804:2012+A2:2019/AC:2021
Declared unit
1 m2 of product of a window ≤ 2,3 m² (reference dimensions according to EN 17213: 1,23 m × 1,48 m)
System boundary
Cradle to gate with other options (A1 - A3, A4, A5, C1 - C4, D)
Product specificity
Product Specific
Manufacturing specificity
Facility Specific
Manufacturing plant
VELUX, Northumberland, UK (Blyth Riverside Business Park, Spencer Road, Blyth, Northumberland NE24 5TG, UK)
Product category
Openings › TranslucentWallAndRoofAssemblies
Product SKU
RO16
Product service life
30 years
Verifier
Rifat Karim, Independent Consultant
LCA software
SimaPro 10.2
Program instructions
Smart EPD General Program Instructions v.2.0, March 2025

Life cycle assessment results

Results per 1 m2 of product of a window ≤ 2,3 m² (reference dimensions according to EN 17213: 1,23 m × 1,48 m).

Environmental Impact Assessment Results

IndicatorUnitA1-A3A4A5C1C2C3C4D
GWP-totalkg CO2 eq2.62e+25.54e+01.35e+106.00e-17.77e+12.28e-2-8.51e+1
GWP-biogenickg CO2 eq-1.77e+04.41e-31.17e+004.78e-45.98e-35.12e-61.50e-1
GWP-fossilkg CO2 eq2.63e+25.53e+01.24e+105.99e-17.77e+12.28e-2-8.52e+1
GWP-luluckg CO2 eq4.67e-12.70e-31.42e-202.92e-45.90e-42.71e-6-1.07e-1
ODPkg CFC11 eq2.49e-51.26e-77.58e-701.36e-88.00e-83.44e-10-3.58e-6
APmol H+ eq1.16e+01.37e-23.67e-201.48e-31.77e-22.06e-4-2.73e-1
EP-freshwaterkg P eq6.66e-24.08e-42.03e-304.42e-52.33e-41.16e-6-1.21e-2
EP-marinekg N eq2.54e-13.73e-38.44e-304.04e-41.01e-29.25e-5-5.14e-2
EP-terrestrialmol N eq2.52e+03.83e-28.29e-204.15e-38.63e-21.01e-3-5.43e-1
POCPkg NMVOC eq9.20e-12.24e-23.00e-202.42e-32.17e-23.03e-4-2.00e-1
ADP-minerals&metalskg Sb eq1.70e-31.55e-55.18e-501.68e-63.74e-68.18e-92.86e-4
ADP-fossilMJ5.29e+38.40e+11.63e+209.09e+01.44e+12.92e-1-1.10e+3
WDPm3 depriv.7.95e+14.01e-12.62e+004.34e-23.53e+06.51e-4-8.35e+0

Resource Use Indicators

IndicatorUnitA1-A3A4A5C1C2C3C4D
PEREMJ4.94e+21.23e+01.49e+101.33e-15.89e-12.41e-3-3.69e+1
PERMMJ9.81e+002.94e-100000
PERTMJ5.04e+21.23e+01.52e+101.33e-15.89e-12.41e-3-3.69e+1
PENREMJ5.29e+38.40e+11.63e+209.10e+01.44e+12.92e-1-1.10e+3
PENRMMJ1.94e+03.54e-35.85e-203.84e-46.33e-43.43e-67.44e-3
PENRTMJ5.29e+38.40e+11.63e+209.10e+01.44e+12.92e-1-1.10e+3
SMkg1.68e+005.05e-200000
RSFMJ00000000
NRSFMJ00000000
FWm31.72e+01.14e-25.89e-201.23e-31.11e-11.57e-5-2.47e-1

Waste and Output Flow Indicators

IndicatorUnitA1-A3A4A5C1C2C3C4D
HWDkg00000000
NHWDkg1.76e-104.40e-10007.98e+00
RWDkg9.43e-32.56e-52.84e-402.77e-67.29e-63.44e-8-1.36e-4
CRUkg00000000
MFRkg1.64e+007.60e+0005.33e+000
MERkg8.56e-102.56e+0003.28e+100
EEMJ1.17e+103.29e+1004.93e+200

Carbon Emissions and Removals

IndicatorUnitA1-A3A4A5C1C2C3C4D
Bio Carbon Removal from Productkg CO200000000
Bio Carbon Emission from Productkg CO200000000
Bio Carbon Removal from Packagingkg CO2-1.63e+10000000
Bio Carbon Emission from Packagingkg CO22.81e+001.35e+100000
Bio Carbon Emission from Waste during Manufacturing (renewable source)kg CO200000000
Calcination Carbon Removalkg CO200000000
Carbonation Carbon Emissionkg CO200000000
Carbon Emission from Waste during Manufacturing (non-renewable source)kg CO200000000

ND = not declared. Life cycle modules: A1-A3 product stage, A4-A5 construction process, B use stage, C end of life, D benefits and loads beyond the system boundary.

Material composition

Product composition
Material/Component CategoryOrigin% Mass
GlazingUK12.7
Profile supportUK8.27
RivetUK0.090
Screws and nutsUK0.840
SealingUK, NL21.6
Small partsUK0.480
UpstandUK, DK56.1
Packaging
Packaging materialOriginMass (kg)
Cardboard8.12
Pallet0.05
Plastic cover0.98
Biogenic carbon
Biogenic carbon contentkg C per m2
Biogenic carbon content in product0
Biogenic carbon content in accompanying packaging3.68

Hazardous substances

No regulated hazardous or dangerous substances are included in this product.

Scenarios

Transport to the building site (A4)

Fuel type
Diesel
Vehicle type
Truck and Trailer
Transport distance
1000 km
Capacity utilization
33%
Weight of products transported
55.24 kg
Packaging mass
9.14 kg

End of life (C1-C4)

Collected with mixed construction waste
46.1 kg
Recycling
5.33 kg
Landfill
7.98 kg
Incineration
32.8 kg

Benefits and loads beyond the system boundary (D)

Recycling rate of product
0.116%

Product description

Automatic Opening Vent (AOV) Rooflights serve as essential safety systems that simultaneously enhance building comfort by providing natural light, daily ventilation, and roof access. These electrically operated natural smoke and heat exhaust ventilators (NSHEV) are rigorously designed, tested, and CE-marked in accordance with BS EN 12101-2, ensuring they open to 140° in under 60 seconds for rapid and effective smoke clearance. Engineered for straightforward installation on flat roofs with pitches up to 15°, the units feature variable kerb heights and a thermally broken profile to significantly reduce the risk of condensation. With options for standard and bespoke sizes, as well as dual-colour finishes to coordinate with both external roofscapes and internal décor, they offer a compliant and versatile solution that does not compromise on architectural aesthetics.

Interpretation

* The manufacturing of the products in this analysis involves the direct procurement of raw materials from suppliers. These materials are then transported to manufacturing facilities in the EU where they are stored, processed, and combined to produce finished products. Notably, the product stage (stage 1) has the highest impact contribution, mainly attributed to the combined environmental impacts associated with raw material manufacturing and energy used in manufacturing the products.

* For products with significant manufacturing energy impacts, the shift to renewable energy sources is recommended.

* Given that the raw materials used in product manufacturing have a significant impact, exploration of opportunities to substitute these materials with alternatives that have a lower environmental impact. Additionally, consideration should be given to collaborating with suppliers who employ sustainable manufacturing techniques or integrate more renewable energy into their production processes. Such initiatives can lead to more environmentally friendly products and further enhance the sustainability of the products in this analysis.

LCIA results are relative expressions and do not predict impacts on category endpoints, the exceeding of thresholds, safety margins or risks. EPDs are comparable only when they follow the same PCR, functional unit and system boundary. The full EPD (PDF) contains the methodology, scenario assumptions and verification statement.