Smart EPD
BUR Non-Modified Asphalt Roofing

Environmental Product Declaration

BUR Non-Modified Asphalt Roofing

by CertainTeed Saint-Gobain

Environmental Product Declaration (EPD) for BUR Non-Modified Asphalt Roofing, manufactured by CertainTeed Saint-Gobain. Declaration SmartEPD-2025-060-0388-01.1, prepared according to UL Part B: Asphalt Shingles, Built-up Asphalt and Modified Bituminous Membrane Roofing, valid until April 22, 2030.

Download the EPD (PDF)

Declared unit
1 m2 of product
Valid until
April 22, 2030
PCR
UL Part B: Asphalt Shingles, Built-up Asphalt and Modified Bituminous Membrane Roofing

Declaration details

Manufacturer
CertainTeed Saint-Gobain
Program operator
Smart EPD
Declaration number
SmartEPD-2025-060-0388-01.1
Date of issue
April 22, 2025
Valid until
April 22, 2030
Product category rules (PCR)
UL Part B: Asphalt Shingles, Built-up Asphalt and Modified Bituminous Membrane Roofing (version 3)
Standard
ISO 14025:2006 and ISO 21930:2017
Declared unit
1 m2 of product
System boundary
Cradle to gate with other options (A1 - A3, A4, A5, C1 - C4)
Product specificity
Product Average
Manufacturing specificity
Facility Specific
Manufacturing plant
Little Rock (2701 E Roosevelt Rd, Little Rock, AR, USA)
Product category
Asphalt
Verifier
Sarah Curpen
LCA software
Sphera LCA for Experts (formerly GaBi) 10.9
Program instructions
Smart EPD General Program Instructions v.1.0, November 2022

Life cycle assessment results

Results per 1 m2 of product.

Environmental Impact Assessment Results

BUR Non-Modified Asphalt Commercial Roofing Base Sheet + Cap Sheet System
IndicatorUnitA1A2A3A1-A3A4A5C1C2C3C4
GWP-totalkg CO2 eq1.54e+01.91e-11.04e-11.83e+03.43e-13.39e+001.52e-209.83e-2
GWP-fossilkg CO2 eq1.54e+01.91e-16.75e-12.40e+03.43e-13.39e+001.52e-209.87e-2
ODPkg CFC 11 eq3.01e-137.17e-123.95e-93.95e-91.29e-115.13e-1305.72e-1304.77e-15
APkg SO2 eq2.97e-31.14e-31.48e-35.60e-32.05e-39.69e-309.09e-505.17e-4
EPkg N eq2.14e-46.31e-58.20e-41.10e-31.14e-44.05e-405.04e-602.22e-5
POCPkg O3 eq3.82e-42.90e-54.20e-48.31e-45.22e-56.69e-402.31e-603.98e-5
ADP-fossilMJ3.24e+03.35e-11.35e+04.92e+06.05e-11.20e+102.68e-201.96e-1
BUR Non-Modified Asphalt Base Sheets
IndicatorUnitA1A2A3A1-A3A4A5C1C2C3C4
GWP-totalkg CO2 eq4.75e-15.75e-23.31e-25.66e-18.44e-21.61e+003.73e-302.48e-2
GWP-fossilkg CO2 eq4.76e-15.75e-21.72e-17.05e-18.44e-21.61e+003.73e-302.49e-2
ODPkg CFC 11 eq1.46e-132.15e-129.62e-109.64e-103.15e-121.72e-1301.39e-1301.16e-15
APkg SO2 eq1.30e-33.41e-43.61e-42.01e-35.00e-44.70e-302.21e-501.26e-4
EPkg N eq9.42e-51.89e-51.99e-43.13e-42.77e-51.93e-401.23e-605.41e-6
POCPkg O3 eq9.83e-58.68e-61.02e-42.09e-41.27e-53.25e-405.63e-709.69e-6
ADP-fossilMJ9.42e-11.00e-13.29e-11.37e+01.47e-15.71e+006.52e-304.77e-2
BUR Non-Modified Asphalt Cap Sheets
IndicatorUnitA1A2A3A1-A3A4A5C1C2C3C4
GWP-totalkg CO2 eq1.06e+01.33e-17.10e-21.26e+02.59e-11.78e+001.15e-207.35e-2
GWP-fossilkg CO2 eq1.06e+01.33e-15.03e-11.69e+02.59e-11.78e+001.15e-207.38e-2
ODPkg CFC 11 eq1.55e-135.02e-122.99e-92.99e-99.79e-123.41e-1304.33e-1303.61e-15
APkg SO2 eq1.67e-37.98e-41.12e-33.59e-31.55e-34.99e-306.88e-503.91e-4
EPkg N eq1.20e-44.42e-56.20e-47.84e-48.61e-52.12e-403.81e-601.68e-5
POCPkg O3 eq2.84e-42.03e-53.18e-46.22e-43.95e-53.44e-401.75e-603.01e-5
ADP-fossilMJ2.30e+02.35e-11.02e+03.55e+04.58e-16.29e+002.03e-201.48e-1

Resource Use Indicators

BUR Non-Modified Asphalt Commercial Roofing Base Sheet + Cap Sheet System
IndicatorUnitA1A2A3A1-A3A4A5C1C2C3C4
RPREMJ2.80e+003.16e+13.44e+104.98e+00001.88e-1
RPRMMJ2.30e-115.60e-141.53e+01.53e+01.25e-132.28e-102.50e-1406.09e-12
RPRTMJ2.80e+05.60e-143.32e+13.60e+11.25e-135.20e+002.50e-1401.88e-1
NRPREMJ2.68e+12.44e+01.52e+14.44e+14.40e+08.82e+101.94e-101.51e+0
NRPRMMJ1.92e-43.22e-55.08e-52.75e-47.14e-56.47e-401.44e-505.84e-5
NRPRTMJ2.68e+12.44e+01.52e+14.44e+14.40e+08.82e+101.94e-101.51e+0
SMkg0000000000
RSFMJ0000000000
NRSFMJ0000000000
FWm34.84e-305.68e-31.05e-207.58e-30001.95e-4
BUR Non-Modified Asphalt Commercial Roofing Base Sheet
IndicatorUnitA1A2A3A1-A3A4A5C1C2C3C4
RPREMJ1.23e+002.32e+12.44e+102.47e+00004.55e-2
RPRMMJ1.14e-111.39e-147.63e-17.63e-13.00e-141.14e-106.04e-1501.47e-12
RPRTMJ1.23e+01.39e-142.40e+12.52e+13.00e-142.58e+006.04e-1504.55e-2
NRPREMJ8.47e+07.29e-16.59e+01.58e+11.07e+04.20e+104.73e-203.67e-1
NRPRMMJ8.47e+07.29e-16.59e+01.58e+11.07e+04.20e+10ND01.41e-5
NRPRTMJNDNDNDNDNDND04.73e-203.67e-1
SMkg0000000000
RSFMJ0000000000
NRSFMJ0000000000
FWm32.12e-303.48e-35.60e-303.76e-30004.74e-5
BUR Non-Modified Asphalt Cap Sheets
IndicatorUnitA1A2A3A1-A3A4A5C1C2C3C4
RPREMJ, net calorific value1.57e+008.40e+09.97e+002.51e+00001.42e-1
RPRMMJ, net calorific value1.16e-114.21e-147.63e-17.63e-19.45e-141.14e-101.90e-1404.62e-12
RPRTMJ, net calorific value1.57e+04.21e-149.16e+01.07e+19.45e-142.62e+001.90e-1401.42e-1
NRPREMJ, net calorific value1.83e+11.71e+08.61e+02.86e+13.33e+04.62e+101.47e-101.14e+0
NRPRMMJ, net calorific value1.02e-42.42e-52.54e-51.52e-45.42e-53.31e-401.09e-504.43e-5
NRPRTMJ, net calorific value1.83e+11.71e+08.61e+02.86e+13.33e+04.62e+101.47e-101.14e+0
SMkg0000000000
RSFMJ, net calorific value0000000000
NRSFMJ, net calorific value0000000000
REMJ0000000000
FWm32.72e-302.21e-34.93e-303.82e-30001.48e-4

Waste and Output Flow Indicators

BUR Non-Modified Asphalt Commercial Roofing Base Sheet + Cap Sheet System
IndicatorUnitA1A2A3A1-A3A4A5C1C2C3C4
HWDkg7.07e-904.25e-91.13e-801.36e-80003.73e-10
NHWDkg1.00e-103.71e-14.71e-106.39e-10004.61e+0
HLRWkg1.06e-602.08e-71.27e-601.12e-60001.80e-8
ILLRWkg8.95e-401.74e-41.07e-301.03e-30001.60e-5
CRUkg0000000000
MFRkg0000000000
MERkg0000000000
MNERkg0000000000
EEEMJ0000000000
EETMJ0000000000
BUR Non-Modified Asphalt Commercial Roofing Base Sheet
IndicatorUnitA1A2A3A1-A3A4A5C1C2C3C4
HWDkg2.80e-901.03e-93.83e-906.52e-90009.06e-11
NHWDkg4.26e-209.01e-21.33e-102.60e-10001.12e+0
HLRWkg4.59e-705.05e-85.10e-705.55e-70004.36e-9
ILLRWkg3.87e-404.23e-54.29e-405.08e-40003.90e-6
CRUkg0000000000
MFRkg0000000000
MERkg00000000ND0
MNERkg0000ND00000
EEEMJ0000000000
EETMJ00000000ND0
BUR Non-Modified Asphalt Cap Sheets
IndicatorUnitA1A2A3A1-A3A4A5C1C2C3C4
HWDkg2.80e-901.03e-93.83e-906.52e-90009.06e-11
NHWDkg4.26e-209.01e-21.33e-102.60e-10001.12e+0
HLRWkg4.59e-705.05e-85.10e-705.55e-70004.36e-9
ILLRWkg3.87e-404.23e-54.29e-405.08e-40003.90e-6
CRUkg0000000000
MFRkgNDNDNDNDNDNDNDNDNDND
MERkgNDNDNDNDNDNDNDNDNDND
MNERkgNDNDNDNDNDNDNDNDNDND
EEEMJNDNDNDNDNDNDNDNDNDND
EETMJNDNDNDNDNDNDNDNDNDND

Carbon Emissions and Removals

IndicatorUnitA1A2A3A1-A3A4A5C1C2C3C4
BCRPkg CO2-2.06e-1NDND-2.06e-1NDNDNDNDNDND
BCEPkg CO2NDNDNDNDNDNDNDNDND2.06e-1
BCRKkg CO2NDND-2.61e-1-2.61e-1NDNDNDNDNDND
BCEKkg CO20000ND2.61e-1NDNDNDND
BCEWkg CO2NDNDNDNDNDNDNDNDNDND
CCEkg CO2NDNDNDNDNDNDNDNDNDND
CCRkg CO2NDNDNDNDNDNDNDNDNDND
CWNRkg CO2NDNDNDNDNDNDNDNDNDND

ND = not declared. Life cycle modules: A1-A3 product stage, A4-A5 construction process, B use stage, C end of life, D benefits and loads beyond the system boundary.

Material composition

Product composition
Material/Component CategoryOrigin% Mass
Fiberglass MatUS2.0 - 8.0
SandUS6 - 34
AsphaltUS20-30
LimestoneUS20-30
GranulesUS40-50
Packaging
Packaging materialOriginMass (kg)
PalletUS0.18
CoreUS0.07
BagCanada0.02
Stretch FilmUS0.02
Biogenic carbon
Biogenic carbon contentkg C per m2
Biogenic carbon content in product0.06
Biogenic carbon content in accompanying packaging0.261

Hazardous substances

No hazardous substances in this product.

Scenarios

Transport to the building site (A4)

Fuel type
Diesel
Vehicle type
Standard Freight Trailer
Transport distance
800 km
Capacity utilization
100%
Packaging mass
0.41 kg

End of life (C1-C4)

Collected with mixed construction waste
4.61 kg
Landfill
4.61 kg
Product or material for final disposal
4.61 kg

Product description

Commercial Roofing systems for low-slope roofing are asphalt based systems with a base sheet and a cap sheet. Roof systems may consist of one or multiple materials depending on the desired performance, warranty, and cost. CertainTeed offers over forty roll good products, which equates to hundreds of system configurations and specification options.This EPD is specific to the BUR Non-Modified Asphalt Commercial Roofing products. BUR Non-modified asphalt products are manufactured using an extra strength fiberglass reinforced mat that receives a coating of weathering grade asphalt and is then lightly surfaced with a mineral release agent. BUR Non-Modified Asphalt products provide additional strength and moisture resistance. Reinforcement mats serve as the structure to asphalt based low-slope roll goods. The fiberglass mats are impregnated and coated with asphalt. Fiberglass stands up well to heat and tension. Its inherently high melting point affords superior fire resistance. Fiberglass-reinforced products applied in hot asphalt retain excellent dimensional stability. Additionally, fiberglass has superior tensile strength.

CertainTeed BUR Non-Modified Asphalt Commercial Roofing systems are available only in a Hot Asphalt applied application. Hot asphalt application is proven, durable, and cost-effective, but is limited by fumes/odor, burn risk, and require the availability of trained labor and appropriate equipment. The BUR Non-Modified Asphalt Commercial Roofing Base Sheets and Cap Sheets included in this EPD.

Interpretation

Based on the results of the life cycle assessment, the life cycle impacts are strongly driven by the raw materials and installation phases. Within the raw materials, the mats and granules contributed significantly to the environmental impact potentials. Installation methods vary among the products in the study and installation for specific projects varies widely depending on the project, products used, applications, etc. This makes specific installation data difficult to obtain. Due to the variable nature of the installation methods and materials, the results for the installation phase of the life cycle should be considered highly uncertain.

The results for individual products within each of the product lines specified in this study vary slightly compared to the averages reported in this EPD, typically due to the coatings and presence of fire retardant metals in the raw material composition. Commercial Roofing systems are often comprised of base sheet and cap sheet combinations from different product lines. Environmental impact potentials of specific commercial roofing combinations can be calculated by adding the cradle-to-gate w/options results found in the appendix of a specified base sheet with those of a specified cap sheet.

LCIA results are relative expressions and do not predict impacts on category endpoints, the exceeding of thresholds, safety margins or risks. EPDs are comparable only when they follow the same PCR, functional unit and system boundary. The full EPD (PDF) contains the methodology, scenario assumptions and verification statement.