Smart EPD
Nucor Econiq™ RE CENTRIA Versawall Insulated Metal Panels

Environmental Product Declaration

Nucor Econiq™ RE CENTRIA Versawall Insulated Metal Panels

by Nucor Corporation

Environmental Product Declaration (EPD) for Nucor Econiq™ RE CENTRIA Versawall Insulated Metal Panels, manufactured by Nucor Corporation. Declaration SmartEPD-2026-143-0955-01, prepared according to UL Part B: Insulated Metal Panels, Metal Composite Panels, and Metal Cladding, valid until June 24, 2031.

Download the EPD (PDF)

Declared unit
100 m2 of product
Valid until
June 24, 2031
PCR
UL Part B: Insulated Metal Panels, Metal Composite Panels, and Metal Cladding

Declaration details

Manufacturer
Nucor Corporation
Program operator
Smart EPD
Declaration number
SmartEPD-2026-143-0955-01
Date of issue
June 24, 2026
Valid until
June 24, 2031
Product category rules (PCR)
UL Part B: Insulated Metal Panels, Metal Composite Panels, and Metal Cladding (version 2)
Standard
ISO 14025:2006 and ISO 21930:2017
Declared unit
100 m2 of product
System boundary
Cradle to gate (A1 - A3)
Product specificity
Product Specific
Manufacturing specificity
Facility Specific
Manufacturing plant
Nucor Sheridan (1811 Rock Street, Sheridan, Arkansas 72150, USA)
Product category
Cladding › InsulatedWallPanels
Verifier
Brandie Sebastian
LCA software
Sphera LCA for Experts (formerly GaBi) 10.9
Program instructions
Smart EPD General Program Instructions v.2.0, March 2025

Life cycle assessment results

Results per 100 m2 of product.

Environmental Impact Assessment Results

Sheridan 2-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
GWP-totalkg CO2 eq2.70e+31.41e+23.48e+23.18e+3
ODPkg CFC 11 eq2.39e-54.15e-132.35e-72.41e-5
APkg SO2 eq7.74e+06.80e-12.33e+01.07e+1
EPkg N eq4.51e-15.87e-21.19e-16.29e-1
SFPkg O3 eq1.11e+21.55e+11.75e+11.44e+2
ADP-fossilMJ, LHV3.66e+41.84e+36.12e+34.46e+4
Sheridan 2.5-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
GWP-totalkg CO2 eq3.18e+31.61e+23.48e+23.69e+3
ODPkg CFC 11 eq2.98e-54.74e-132.35e-73.00e-5
APkg SO2 eq9.17e+07.80e-12.33e+01.23e+1
EPkg N eq5.37e-16.71e-21.19e-17.23e-1
SFPkg O3 eq1.31e+21.78e+11.78e+11.66e+2
ADP-fossilMJ, LHV4.37e+42.11e+36.12e+35.20e+4
Sheridan 2.75-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
GWP-totalkg CO2 eq3.02e+31.51e+23.48e+23.52e+3
ODPkg CFC 11 eq3.25e-54.44e-132.35e-73.27e-5
APkg SO2 eq8.83e+07.36e-12.33e+01.19e+1
EPkg N eq5.23e-16.30e-21.19e-17.05e-1
SFPkg O3 eq1.25e+21.67e+11.80e+11.60e+2
ADP-fossilMJ, LHV4.31e+41.98e+36.12e+35.12e+4
Sheridan 3-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
GWP-totalkg CO2 eq2.93e+31.45e+23.48e+23.42e+3
ODPkg CFC 11 eq3.53e-54.25e-132.35e-73.55e-5
APkg SO2 eq8.68e+07.09e-12.33e+01.17e+1
EPkg N eq5.20e-16.04e-21.19e-16.99e-1
SFPkg O3 eq1.22e+21.61e+11.81e+11.56e+2
ADP-fossilMJ, LHV4.31e+41.89e+36.12e+35.11e+4
Sheridan 4-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
GWP-totalkg CO2 eq3.61e+31.71e+23.48e+24.13e+3
ODPkg CFC 11 eq4.69e-55.01e-132.35e-74.71e-5
APkg SO2 eq1.08e+18.43e-12.33e+01.40e+1
EPkg N eq6.51e-17.14e-21.19e-18.41e-1
SFPkg O3 eq1.51e+21.91e+11.87e+11.88e+2
ADP-fossilMJ, LHV5.44e+42.23e+36.12e+36.27e+4

Resource Use Indicators

Sheridan 2-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
RPREMJ2.19e+38.18e+11.05e+41.28e+4
RPRMMJ0NDND0
NRPREMJ4.03e+41.86e+36.31e+34.85e+4
NRPRMMJ2.43e+2NDND2.43e+2
SMkg4.93e+2ND04.93e+2
RSFMJNDND00
NRSFMJNDND00
FWm31.04e+22.72e-11.15e+01.06e+2
REMJNDND00
Sheridan 2.5-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
RPREMJ2.57e+39.35e+11.05e+41.32e+4
RPRMMJ0NDND0
NRPREMJ4.81e+42.13e+36.31e+35.65e+4
NRPRMMJ2.81e+2NDND2.81e+2
SMkg5.72e+2ND05.72e+2
RSFMJNDND00
NRSFMJNDND00
FWm31.21e+23.10e-11.15e+01.23e+2
REMJNDND00
Sheridan 2.75-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
RPREMJ2.41e+38.75e+11.05e+41.30e+4
RPRMMJ0NDND0
NRPREMJ4.72e+41.99e+36.31e+35.55e+4
NRPRMMJ2.55e+2NDND2.55e+2
SMkg5.18e+2ND05.18e+2
RSFMJNDND00
NRSFMJNDND00
FWm31.11e+22.90e-11.15e+01.12e+2
REMJNDND00
Sheridan 3-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
RPREMJ2.31e+38.36e+11.05e+41.29e+4
RPRMMJ0NDND0
NRPREMJ4.71e+41.91e+36.31e+35.53e+4
NRPRMMJ2.37e+2NDND2.37e+2
SMkg4.81e+2ND04.81e+2
RSFMJNDND00
NRSFMJNDND00
FWm31.03e+22.77e-11.15e+01.05e+2
REMJNDND00
Sheridan 4-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
RPREMJ2.82e+39.86e+11.05e+41.35e+4
RPRMMJ0NDND0
NRPREMJ5.92e+42.25e+36.31e+36.78e+4
NRPRMMJ2.82e+2NDND2.82e+2
SMkg5.73e+2ND05.73e+2
RSFMJNDND00
NRSFMJNDND00
FWm31.24e+23.27e-11.15e+01.25e+2
REMJNDND00

Waste and Output Flow Indicators

Sheridan 2-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
HWDkg1.41e+0N/A2.07e+03.48e+0
NHWDkg1.84e+1N/A3.63e+15.47e+1
HLRWkg1.03e-36.65e-63.35e-51.07e-3
ILLRWkg7.85e-15.60e-32.99e-28.21e-1
CRUkgN/AN/AN/AN/A
MRkg2.85e+1N/A1.63e+21.91e+2
MERkgN/AN/A00
EEMJ, LHVN/AN/A00
Sheridan 2.5-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
HWDkg1.63e+0N/A2.07e+03.70e+0
NHWDkg2.13e+1N/A3.63e+15.76e+1
HLRWkg1.23e-37.60e-63.35e-51.27e-3
ILLRWkg9.31e-16.40e-32.99e-29.67e-1
CRUkgN/AN/AN/AN/A
MRkg3.30e+1N/A1.63e+21.96e+2
MERkgN/AN/A00
EEMJ, LHVN/AN/A00
Sheridan 2.75-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
HWDkg1.48e+0N/A2.07e+03.55e+0
NHWDkg1.93e+1N/A3.63e+15.56e+1
HLRWkg1.20e-37.12e-63.35e-51.24e-3
ILLRWkg8.98e-16.00e-32.99e-29.34e-1
CRUkgN/AN/AN/AN/A
MRkg2.99e+1N/A1.63e+21.93e+2
MERkgN/AN/A00
EEMJ, LHVN/AN/A00
Sheridan 3-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
HWDkg1.37e+0N/A2.07e+03.44e+0
NHWDkg1.79e+1N/A3.63e+15.42e+1
HLRWkg1.20e-36.81e-63.35e-51.24e-3
ILLRWkg8.84e-15.74e-32.99e-29.19e-1
CRUkgN/AN/AN/AN/A
MRkg2.78e+1N/A1.63e+21.90e+2
MERkgN/AN/A00
EEMJ, LHVN/AN/A00
Sheridan 4-Inch Econiq™ RE CENTRIA Versawall Panels
IndicatorUnitA1A2A3A1-A3
HWDkg1.63e+0N/A2.07e+03.71e+0
NHWDkg2.13e+1N/A3.63e+15.76e+1
HLRWkg1.50e-38.04e-63.35e-51.54e-3
ILLRWkg1.10e+06.77e-32.99e-21.14e+0
CRUkgN/AN/AN/AN/A
MRkg3.31e+1N/A1.63e+21.96e+2
MERkgN/AN/A00
EEMJ, LHVN/AN/A00

ND = not declared. Life cycle modules: A1-A3 product stage, A4-A5 construction process, B use stage, C end of life, D benefits and loads beyond the system boundary.

Material composition

Product composition
Material/Component Category1.5"2"2.5"2.75"3"4"5"6"7"8"Unit
Steel SheetN/A81%80%76%73%71%N/AN/AN/AN/A% by mass
PIR Foam InsulationN/A19%20%24%27%29%N/AN/AN/AN/A% by mass
Packaging
Packaging materialOriginMass (kg)
Interleaf3.1
Foam Sheet4.7
Oriented Strandboard149
Cardboard24.9
Plastic Wrap3.6
Foam Feet2.9
Front/End Cap0.2
Biogenic carbon
Biogenic carbon contentkg C per 100 m2
Biogenic carbon content in product0
Biogenic carbon content in accompanying packaging0

Hazardous substances

No regulated hazardous or dangerous substances are included in this product.

Product description

CENTRIA insulated metal panels (IMPs) consist of polyisocyanurate (PIR) foam between two sheets of galvanized steel. Several configurations of IMPs exist depending on where and how they are used (e.g. building walls, roofs, cold storage, etc.) and the styling as desired by the architect. Additionally, IMPs can be manufactured either on a continuous or discontinuous manufacturing line. CENTRIA panels are comprised of an advanced PIR core that is injected between two pre-finished steel sheets, forming a single, all-in-one unit. The result is a highly thermal efficient insulated panel. Finished panels are mounted to the building's framework, outboard of the structural supports and provide continuous insulation with no thermal bridges for maximum thermal efficiency. CENTRIA panels meet or exceed code requirements for foam plastic insulation.

Information for CENTRIA Versawall panels was supplied by one (1) Nucor IPG facility located in Sheridan, AR, USA.

IMP are used for exterior wall and roof cladding systems as well as interior ceilings and wall partitions. They are installed in an array of industries including automotive, food production, EV battery plants, data centers, aviation, storage facilities, stadiums, healthcare, education, manufacturing, warehousing and more. IMPs are available in variety of configurations depending on the customer’s requirements, including panel profile, thickness, module, paint system and color.

In addition, Nucor manufactures steel to various customer-specific standards. The IMP core thickness varies according to building site. Therefore, this EPD reports LCA results for each thickness separately.

CENTRIA’s commercial & industrial insulated metal panels deliver the industry's best combination of aesthetics, performance, sustainability and value. These lightweight panels provide tremendous flexibility with long lengths, various finish options and superior weather resistance, as well as vertical installation capability. These panels are the ideal product to create a modern aesthetic for large-scale buildings like warehouses, industrial facilities, schools and shopping centers.

This EPD is for Econiq™ RE CENTRIA Versawall Insulated Metal Panels, meaning that it accounts for Renewable Energy Credits (RECs) used to balance the impacts associated with grid electricity use for production of the IMP product. The data represented in this EPD is for a limited production volume (1,000 square meters) in 2025. Moving forward, Nucor will complete an annual end of year review with Smart EPD of actual RECs purchased and retired over the previous calendar year and update the EPD as needed. The RECs will be purchased and retired during the same period as represented by the EPD.[

Interpretation

In order to facilitate a more detailed understanding of the contributions from different processes, an analysis is included in this section which details the contribution from Modules A1, A2, and A3.

The impact assessment results indicate that Module A1, i.e. Raw Materials, is the largest contributor to potential environmental impact categories for global warming potential, ozone depletion potential, acidification potential, eutrophication potential, smog formation potential, and abiotic resource depletion potential of fossil energy resources. Module A2, i.e. transport to IPG, and Module A3, i.e. manufacturing at the IPG facility, are not the most significant contributor to any impact category.

The use of renewable energy through EACs resulted in a 8.9%-11.3% reduction in the A1-A3 GWP impacts.

LCIA results are relative expressions and do not predict impacts on category endpoints, the exceeding of thresholds, safety margins or risks. EPDs are comparable only when they follow the same PCR, functional unit and system boundary. The full EPD (PDF) contains the methodology, scenario assumptions and verification statement.