Environmental Product Declaration
Key #597 MVT - Epoxy Moisture Mitigation Primer
Environmental Product Declaration (EPD) for Key #597 MVT - Epoxy Moisture Mitigation Primer, manufactured by Key Resin Company. Declaration SmartEPD-2025-096-0642-01.1, prepared according to NSF PCR for Resinous Floor Coatings, valid until November 4, 2030.
- Functional unit
- 1 m2 of product of covered and protected flooring surface for a period of 60 years
- Valid until
- November 4, 2030
- PCR
- NSF PCR for Resinous Floor Coatings
Declaration details
- Manufacturer
- Key Resin Company
- Program operator
- Smart EPD
- Declaration number
- SmartEPD-2025-096-0642-01.1
- Date of issue
- November 4, 2025
- Valid until
- November 4, 2030
- Product category rules (PCR)
- NSF PCR for Resinous Floor Coatings (version 1e)
- Standard
- ISO 14025:2006 and ISO 21930:2017
- Functional unit
- 1 m2 of product of covered and protected flooring surface for a period of 60 years
- System boundary
- Cradle to grave (A1 - A3, A4, A5, B1 - B7, C1 - C4, D)
- Product specificity
- Product Specific
- Manufacturing specificity
- Manufacturer Average
- Manufacturing plants
- Key Resin Phoenix (4330 N 43rd Ave, Phoenix, AZ 85031, USA); Key Resin, Batavia, OH (4050 Clough Woods Drive, Batavia, OH 45103, USA)
- Product category
- Finishes › Flooring › OtherFlooring
- Product SKU
- Key #597-MVT
- Product service life
- 5 years
- Verifier
- Mari Kirss
- LCA software
- SimaPro 9.5
- Program instructions
- Smart EPD General Program Instructions v.2.0, March 2025
Life cycle assessment results
Results per 1 m2 of product of covered and protected flooring surface for a period of 60 years.
Environmental Impact Assessment Results
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 | D |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GWP-total | kg CO2-eq | 6.26e-1 | 3.70e-2 | 1.34e-2 | 0 | 6.14e+0 | 0 | 7.44e+0 | 0 | 0 | 0 | 0 | 7.87e-3 | 0 | 4.72e-1 | -4.49e-1 |
| ODP | kg CFC-11 eq | 3.24e-8 | 6.35e-10 | 6.63e-10 | 0 | 1.85e-7 | 0 | 3.71e-7 | 0 | 0 | 0 | 0 | 1.35e-10 | 0 | 1.29e-8 | -1.09e-8 |
| AP | kg SO2 eq | 2.19e-3 | 1.18e-4 | 4.67e-5 | 0 | 2.34e-2 | 0 | 2.59e-2 | 0 | 0 | 0 | 0 | 2.51e-5 | 0 | 1.63e-3 | -1.66e-3 |
| EP | kg N eq | 2.98e-3 | 3.26e-5 | 6.03e-5 | 0 | 2.87e-2 | 0 | 3.38e-2 | 0 | 0 | 0 | 0 | 6.93e-6 | 0 | 1.63e-3 | -1.67e-3 |
| POCP | kg O3 eq | 2.80e-2 | 2.71e-3 | 6.31e-4 | 0 | 3.24e-1 | 0 | 3.45e-1 | 0 | 0 | 0 | 0 | 5.75e-4 | 0 | 2.65e-2 | -2.47e-2 |
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 | D |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GWP-total | kg CO2-eq | 6.26e-1 | 3.70e-2 | 1.34e-2 | 0 | 6.14e+0 | 0 | 7.44e+0 | 0 | 0 | 0 | 0 | 7.87e-3 | 0 | 4.72e-1 | -4.49e-1 |
| ODP | kg CFC-11 eq | 3.24e-8 | 6.35e-10 | 6.63e-10 | 0 | 1.85e-7 | 0 | 3.71e-7 | 0 | 0 | 0 | 0 | 1.35e-10 | 0 | 1.29e-8 | -1.09e-8 |
| AP | kg SO2 eq | 2.19e-3 | 1.18e-4 | 4.67e-5 | 0 | 2.34e-2 | 0 | 2.59e-2 | 0 | 0 | 0 | 0 | 2.51e-5 | 0 | 1.63e-3 | -1.66e-3 |
| EP | kg N eq | 2.98e-3 | 3.26e-5 | 6.03e-5 | 0 | 2.87e-2 | 0 | 3.38e-2 | 0 | 0 | 0 | 0 | 6.93e-6 | 0 | 1.63e-3 | -1.67e-3 |
| POCP | kg O3 eq | 2.80e-2 | 2.71e-3 | 6.31e-4 | 0 | 3.24e-1 | 0 | 3.45e-1 | 0 | 0 | 0 | 0 | 5.75e-4 | 0 | 2.65e-2 | -2.47e-2 |
Resource Use Indicators
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 | D |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RPRE | MJ | 6.59e-1 | 6.82e-3 | 1.33e-2 | 0 | 5.33e+1 | 0 | 7.47e+0 | 0 | 0 | 0 | 0 | 1.45e-3 | 0 | 1.84e+0 | -4.26e-1 |
| RPRM | MJ | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| RPRT | MJ | 6.59e-1 | 6.82e-3 | 1.33e-2 | 0 | 5.33e+1 | 0 | 7.47e+0 | 0 | 0 | 0 | 0 | 1.45e-3 | 0 | 1.84e+0 | -4.26e-1 |
| NRPRE | MJ | 8.25e+0 | 5.38e-1 | 1.78e-1 | 0 | 8.81e+1 | 0 | 9.86e+1 | 0 | 0 | 0 | 0 | 1.14e-1 | 0 | 5.28e+0 | -4.97e+0 |
| NRPRM | MJ | 2.20e+0 | 0 | 4.39e-2 | 0 | 0 | 0 | 2.46e+1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | -8.84e-2 |
| NRPRT | MJ | 1.26e+1 | 5.38e-1 | 2.65e-1 | 0 | 8.81e+1 | 0 | 1.48e+2 | 0 | 0 | 0 | 0 | 1.14e-1 | 0 | 5.28e+0 | -5.15e+0 |
| ADPF | MJ | 1.25e+0 | 7.55e-2 | 2.67e-2 | 0 | 1.03e+1 | 0 | 1.48e+1 | 0 | 0 | 0 | 0 | 1.60e-2 | 0 | 3.25e-1 | -3.01e-1 |
| FW | m3 | 8.04e-3 | 7.03e-5 | 1.63e-4 | 0 | 1.07e+0 | 0 | 9.10e-2 | 0 | 0 | 0 | 0 | 1.49e-5 | 0 | 2.27e-3 | -2.20e-3 |
| RE | MJ | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| NRSF | MJ | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| RSF | MJ | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| SM | kg | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 | D |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RPRE | MJ | 6.59e-1 | 6.82e-3 | 1.33e-2 | 0 | 5.33e+1 | 0 | 7.47e+0 | 0 | 0 | 0 | 0 | 1.45e-3 | 0 | 1.84e+0 | -4.26e-1 |
| RPRM | MJ | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| RPRT | MJ | 6.59e-1 | 6.82e-3 | 1.33e-2 | 0 | 5.33e+1 | 0 | 7.47e+0 | 0 | 0 | 0 | 0 | 1.45e-3 | 0 | 1.84e+0 | -4.26e-1 |
| NRPRE | MJ | 8.25e+0 | 5.38e-1 | 1.78e-1 | 0 | 8.81e+1 | 0 | 9.86e+1 | 0 | 0 | 0 | 0 | 1.14e-1 | 0 | 5.28e+0 | -4.97e+0 |
| NRPRM | MJ | 2.20e+0 | 0 | 4.39e-2 | 0 | 0 | 0 | 2.46e+1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | -8.84e-2 |
| NRPRT | MJ | 1.26e+1 | 5.38e-1 | 2.65e-1 | 0 | 8.81e+1 | 0 | 1.48e+2 | 0 | 0 | 0 | 0 | 1.14e-1 | 0 | 5.28e+0 | -5.15e+0 |
| ADPF | MJ | 1.25e+0 | 7.55e-2 | 2.67e-2 | 0 | 1.03e+1 | 0 | 1.48e+1 | 0 | 0 | 0 | 0 | 1.60e-2 | 0 | 3.25e-1 | -3.01e-1 |
| FW | m3 | 8.04e-3 | 7.03e-5 | 1.63e-4 | 0 | 1.07e+0 | 0 | 9.10e-2 | 0 | 0 | 0 | 0 | 1.49e-5 | 0 | 2.27e-3 | -2.20e-3 |
| RE | MJ | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| NRSF | MJ | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| RSF | MJ | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| SM | kg | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Waste and Output Flow Indicators
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 | D |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| HWD | kg | 3.36e-4 | 0 | 6.73e-6 | 0 | 0 | 0 | 3.77e-3 | 0 | 0 | 0 | 0 | 0 | 0 | 2.33e+0 | 0 |
| NHWD | kg | 4.02e-3 | 0 | 1.25e-2 | 0 | 0 | 0 | 1.82e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| MR | kg | 2.67e-3 | 0 | 1.65e-2 | 0 | 0 | 0 | 2.11e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| MER | kg | 4.50e-4 | 0 | 9.00e-6 | 0 | 0 | 0 | 5.05e-3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| ILLRW | m3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| HLLRW | m3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| CRU | kg | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| EE | MJ | 1.39e-2 | 0 | 2.77e-4 | 0 | 0 | 0 | 1.55e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 | D |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| HWD | kg | 3.36e-4 | 0 | 6.73e-6 | 0 | 0 | 0 | 3.77e-3 | 0 | 0 | 0 | 0 | 0 | 0 | 2.33e+0 | 0 |
| NHWD | kg | 4.02e-3 | 0 | 1.25e-2 | 0 | 0 | 0 | 1.82e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| MR | kg | 2.67e-3 | 0 | 1.65e-2 | 0 | 0 | 0 | 2.11e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| MER | kg | 4.50e-4 | 0 | 9.00e-6 | 0 | 0 | 0 | 5.05e-3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| ILLRW | m3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| HLLRW | m3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| CRU | kg | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| EE | MJ | 1.39e-2 | 0 | 2.77e-4 | 0 | 0 | 0 | 1.55e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Carbon Emissions and Removals
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 | D |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bio Carbon Removal from Product | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Bio Carbon Emission from Product | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Bio Carbon Removal from Packaging | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Bio Carbon Emission from Packaging | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Bio Carbon Emission from Waste during Manufacturing (renewable source) | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Calcination Carbon Removal | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Carbonation Carbon Emission | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Carbon Emission from Waste during Manufacturing (non-renewable source) | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 | D |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bio Carbon Removal from Product | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Bio Carbon Emission from Product | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Bio Carbon Removal from Packaging | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Bio Carbon Emission from Packaging | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Bio Carbon Emission from Waste during Manufacturing (renewable source) | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Calcination Carbon Removal | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Carbonation Carbon Emission | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Carbon Emission from Waste during Manufacturing (non-renewable source) | kg CO2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
ND = not declared. Life cycle modules: A1-A3 product stage, A4-A5 construction process, B use stage, C end of life, D benefits and loads beyond the system boundary.
Material composition
| Material/Component Category | Origin | % Mass |
|---|---|---|
| Solvent | US | 40 - 60 |
| curing agent | US | 22 - 33 |
| reactive diluent | US | < 10 |
| resin | US | 15 - 22 |
| Packaging material | Origin | Mass (kg) |
|---|---|---|
| Steel pail packaging | 0.03 |
| Biogenic carbon content | kg C per m2 |
|---|---|
| Biogenic carbon content in product | 0 |
| Biogenic carbon content in accompanying packaging | 0 |
Hazardous substances
Alkyl glycidyl ether (68609-97-2)
Bisphenol A Polyglycidyl Ether Resin (25068-38-6)
Scenarios
End of life (C1-C4)
- Collected separately
- 0.0456 kg
- Collected with mixed construction waste
- 0.1862 kg
- Landfill
- 0.19 kg
Product description
KEY #597-MVT is a low viscosity, water-emulsion, penetrating epoxy primer designed for use as a moisture vapor treatment on concrete floor slabs with excessive moisture vapor emission rates or a high internal moisture content. KEY #597-MVT will tolerate moisture vapor emission rates (MVER) up to 20 lbs moisture per 1,000 square feet per 24 hours when tested in accordance with ASTM F1869. When tested in accordance with ASTM F2170 it will tolerate up to 99% relative humidity. If moisture tests exceed these limits contact Key Resin Technical Service for recommendations.
Interpretation
Raw materials are sourced from suppliers, transported to manufacturing facilities, and mixed to produce products. The product stage (A1-A3) drives the environmental impact, due to raw material production and energy use. This impacts is amplified in the use phase due to recoatings, making B4 the largest contributor to the overall impact. Market and Technical service life scenarios differ depending on assumed estimated service life (ESL), with lower impacts for longer-lived products. Those scenarios are constructed using PCR prescriptions that are highly conservative, as they assumed the replacement of the full coating system. End-of-life impacts are relatively low, as products are assumed to be landfilled with building demolition waste. Switching to renewable energy is advised for products with high manufacturing energy demands. The manufacturer should explore lower-impact raw materials and work with suppliers using sustainable methods or renewable energy to enhance product sustainability.
LCIA results are relative expressions and do not predict impacts on category endpoints, the exceeding of thresholds, safety margins or risks. EPDs are comparable only when they follow the same PCR, functional unit and system boundary. The full EPD (PDF) contains the methodology, scenario assumptions and verification statement.