Smart EPD
Microflex® Pre-Insulated Piping

Environmental Product Declaration

Microflex® Pre-Insulated Piping

by Watts

Environmental Product Declaration (EPD) for Microflex® Pre-Insulated Piping, manufactured by Watts. Declaration SmartEPD-2026-134-0878-01, prepared according to IBU Part B: Requirements on the EPD for Preinsulated Pipes for District Heating and Cooling, valid until May 29, 2031.

Download the EPD (PDF)

Declared unit
1 rm of product pre-insulated pipe including brass couplings
Valid until
May 29, 2031
PCR
Preinsulated Pipes for District Heating and Cooling

Declaration details

Manufacturer
Watts
Program operator
Smart EPD
Declaration number
SmartEPD-2026-134-0878-01
Date of issue
May 29, 2026
Valid until
May 29, 2031
Product category rules (PCR)
IBU Part B: Requirements on the EPD for Preinsulated Pipes for District Heating and Cooling (version 12)
Standard
EN15804:2012+A2:2019 Sustainability of construction works - Environmental product declarations - Core rules for the product category of construction products
Declared unit
1 rm of product pre-insulated pipe including brass couplings
System boundary
Cradle to grave (A1 - A3, A4, A5, B1 - B7, C1 - C4, D)
Manufacturing specificity
Facility Specific
Manufacturing plant
Gardolo (Via Vienna, 3, Località Produttiva I, Autonomous Province of Trento, Italy)
Product category
UtilityPiping › BuildingHeatingPiping
Product SKU
MD16040C: Microflex DUO heating pipe with a 160 mm outer housing diameter and two 40 mm PE-Xa pipes with an oxygen diffusion barrier. This product was selected as the representative unit as it is the top-selling variant. EPD results are reported for 1 rm (running meter) of MD16040C. Other products…
Verifier
Mari Kirss
LCA software
SimaPro 10.2
Program instructions
Smart EPD General Program Instructions v.2.0, March 2025

Life cycle assessment results

Results per 1 rm of product pre-insulated pipe including brass couplings.

Environmental Impact Assessment Results

Main Scenario - Incineration at End of Life
IndicatorUnitA1A2A3A1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
GWP-totalkg CO2 eq8.49e+01.61e-11.43e+01.01e+19.31e-12.16e-2000000004.21e-28.16e+08.47e-5-6.48e+0
GWP-fossilkg CO2 eq8.50e+01.61e-11.33e+09.99e+09.30e-12.16e-2000000004.21e-28.16e+08.46e-5-6.43e+0
GWP-biogenickg CO2 eq-1.88e-26.78e-59.76e-27.89e-25.55e-41.37e-6000000002.48e-53.06e-45.30e-8-4.61e-2
GWP-luluckg CO2 eq7.04e-36.00e-51.74e-47.27e-33.31e-42.21e-7000000001.43e-53.36e-53.85e-8-4.22e-3
ODPkg CFC 11 eq3.31e-73.03e-91.00e-74.34e-71.86e-81.21e-11000000008.46e-101.40e-91.95e-12-2.55e-7
APmol H+ eq8.69e-21.29e-31.38e-38.96e-24.25e-34.97e-6000000001.89e-41.13e-35.15e-7-1.73e-2
EP-freshwaterkg P eq6.71e-31.03e-55.89e-56.78e-36.41e-56.06e-8000000002.89e-61.78e-58.76e-9-1.73e-3
EP-marinekg N eq9.44e-34.10e-47.74e-41.06e-21.68e-37.85e-6000000007.43e-55.17e-41.99e-7-2.90e-3
EP-terrestrialmol N eq9.51e-24.51e-34.82e-31.04e-11.83e-22.36e-5000000008.10e-45.46e-32.17e-6-2.99e-2
POCPkg NMVOC eq5.56e-21.45e-32.98e-36.00e-26.51e-37.05e-6000000002.91e-41.36e-37.48e-7-1.43e-2
ADP-minerals&metalskg Sb eq9.00e-44.49e-71.19e-69.02e-42.85e-61.67e-9000000001.30e-77.92e-72.08e-10-1.06e-4
ADP-fossilMJ2.34e+22.25e+01.86e+12.55e+21.33e+18.98e-3000000006.02e-19.59e-11.57e-3-1.11e+2
WDPm3 world eq deprived4.32e+01.25e-24.01e+08.34e+07.86e-2-1.17e-3000000003.55e-38.77e-25.26e-5-1.23e+0
PMdisease incidence3.53e-71.40e-81.11e-83.78e-78.89e-86.08e-11000000004.08e-96.07e-91.38e-11-6.11e-8
IRPkBq U235 eq9.74e-12.66e-31.66e-29.93e-11.77e-21.07e-5000000007.97e-42.47e-31.59e-6-8.20e-1
ETP-fwCTUe1.79e+25.61e-13.36e+01.83e+23.45e+09.74e-3000000001.57e-12.79e+04.77e-4-1.87e+1
HTP-cCTUh4.54e-81.01e-92.45e-94.89e-86.28e-95.57e-12000000002.84e-101.18e-91.02e-12-1.19e-8
HTP-ncCTUh7.07e-71.48e-93.86e-97.12e-79.37e-94.53e-11000000004.30e-101.22e-86.11e-13-9.47e-8
SQP-5.13e+11.50e+07.19e-15.35e+19.91e+09.03e-3000000004.50e-13.62e-12.24e-3-8.42e+0
Alternate Scenario - Landfilling at End of Life
IndicatorUnitA1A2A3A1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
GWP-totalkg CO2 eq8.49e+01.61e-11.43e+01.01e+19.31e-12.16e-2000000004.21e-22.40e-23.15e-1-1.36e-1
GWP-fossilkg CO2 eq8.50e+01.61e-11.33e+09.99e+09.30e-12.16e-2000000004.21e-22.39e-23.15e-1-1.36e-1
GWP-biogenickg CO2 eq-1.88e-26.78e-59.76e-27.89e-25.55e-41.37e-6000000002.48e-51.29e-42.42e-4-7.67e-5
GWP-luluckg CO2 eq7.04e-36.00e-51.74e-47.27e-33.31e-42.21e-7000000001.43e-51.15e-51.69e-5-2.13e-4
ODPkg CFC 11 eq3.31e-73.03e-91.00e-74.34e-71.86e-81.21e-11000000008.46e-102.22e-107.62e-10-1.92e-8
APmol H+ eq8.69e-21.29e-31.38e-38.96e-24.25e-34.97e-6000000001.89e-48.38e-52.10e-4-7.44e-3
EP-freshwaterkp P eq6.71e-31.03e-55.89e-56.78e-36.41e-56.06e-8000000002.89e-66.41e-63.15e-6-5.92e-4
EP-marinekg N eq9.44e-34.10e-47.74e-41.06e-21.68e-37.85e-6000000007.43e-51.03e-56.97e-4-4.04e-4
EP-terrestrialmol N eq9.51e-24.51e-34.82e-31.04e-11.83e-22.36e-5000000008.10e-41.16e-48.56e-4-5.49e-3
POCPkg NMVOC eq5.56e-21.45e-32.98e-36.00e-26.51e-37.05e-6000000002.91e-43.93e-53.72e-4-1.60e-3
ADP-minerals&metalskg Sb eq9.00e-44.49e-71.19e-69.02e-42.85e-61.67e-9000000001.30e-76.17e-76.46e-8-1.02e-4
ADP-fossilMJ2.34e+22.25e+01.86e+12.55e+21.33e+18.98e-3000000006.02e-11.52e-16.56e-1-1.99e+0
WDPm3 world eq deprived4.32e+01.25e-24.01e+08.34e+07.86e-2-1.17e-3000000003.55e-34.14e-3-4.18e-1-1.33e-1
PMdisease incidence3.53e-71.40e-81.11e-83.78e-78.89e-86.08e-11000000004.08e-91.44e-94.75e-9-1.79e-8
IRPkBq U235 eq9.74e-12.66e-31.66e-29.93e-11.77e-21.07e-5000000007.97e-41.50e-36.62e-4-1.45e-2
ETP-fwCTUe1.79e+25.61e-13.36e+01.83e+23.45e+09.74e-3000000001.57e-11.29e-11.72e+0-1.08e+1
HTP-cCTUh4.54e-81.01e-92.45e-94.89e-86.28e-95.57e-12000000002.84e-101.30e-101.73e-10-1.42e-9
HTP-ncCTUh7.07e-71.48e-93.86e-97.12e-79.37e-94.53e-11000000004.30e-105.45e-103.03e-9-7.77e-8
SQP-5.13e+11.50e+07.19e-15.35e+19.91e+09.03e-3000000004.50e-11.46e-11.53e+0-2.46e+0

Resource Use Indicators

Main Scenario - Incineration at End of Life
IndicatorUnitA1A2A3A1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
PEREMJ, net calorific value1.32e+13.55e-21.21e+12.53e+12.31e-11.61e-4000000001.04e-24.49e-22.46e-5-7.21e+0
PERMMJ, net calorific value000000000000000000
PERTMJ, net calorific value1.32e+13.55e-21.21e+12.53e+12.31e-11.61e-4000000001.04e-24.49e-22.46e-5-7.21e+0
PENREMJ, net calorific value1.20e+22.25e+01.95e+11.42e+21.33e+16.05e-1000000006.02e-11.13e+21.57e-3-1.11e+2
PENRMMJ, net calorific value1.14e+20-8.75e-11.13e+20-8.37e-1000000000-1.12e+200
PENRTMJ, net calorific value2.34e+22.25e+01.86e+12.55e+21.33e+1-2.32e-1000000006.02e-19.59e-11.57e-3-1.11e+2
SMkg9.76e-2009.76e-200000000000002.46e-2
RSFMJ, net calorific value000000000000000000
NRSFMJ, net calorific value000000000000000000
FWm31.05e-13.06e-49.38e-21.99e-11.93e-3-2.71e-5000000008.73e-52.06e-31.24e-6-3.10e-2
Alternate Scenario - Landfilling at End of Life
IndicatorUnitA1A2A3A1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
PEREMJ, net calorific value1.32e+13.55e-21.21e+12.53e+12.31e-11.61e-4000000001.04e-22.43e-29.84e-3-3.65e-1
PERMMJ, net calorific value000000000000000000
PERTMJ, net calorific value1.32e+13.55e-21.21e+12.53e+12.31e-11.61e-4000000001.04e-22.43e-29.84e-3-3.65e-1
PENREMJ, net calorific value1.20e+22.25e+01.95e+11.42e+21.33e+16.05e-1000000006.02e-11.52e-11.13e+2-1.99e+0
PENRMMJ, net calorific value1.14e+20-8.75e-11.13e+20-8.37e-10000000000-1.12e+20
PENRTMJ, net calorific value2.34e+22.25e+01.86e+12.55e+21.33e+1-2.32e-1000000006.02e-11.52e-16.56e-1-1.99e+0
SMkg9.76e-2009.76e-200000000000002.46e-2
RSFMJ, net calorific value000000000000000000
NRSFMJ, net calorific value000000000000000000
FWm31.05e-13.06e-49.38e-21.99e-11.93e-3-2.71e-5000000008.73e-51.02e-4-9.72e-3-3.26e-3

Waste and Output Flow Indicators

Main Scenario - Incineration at End of Life
IndicatorUnitA1A2A3A1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
HWDkg6.18e-13.28e-32.04e-26.42e-11.93e-21.75e-4000000008.70e-47.37e-23.87e-6-1.34e-1
NHWDkg8.13e+16.57e-26.31e+08.77e+14.07e-14.99e-2000000001.84e-22.86e+07.76e-3-8.05e+0
RWDkg2.50e-46.61e-74.17e-62.55e-44.40e-62.66e-9000000001.98e-76.28e-73.93e-10-2.10e-4
CRUkg000000000000000000
MFRkg000006.30e-30000000001.16e-100
MERkg000000000000000000
EEEMJ000003.20e-20000000001.31e+100
EETMJ000006.21e-20000000002.53e+100
Alternate Scenario - Landfilling at End of Life
IndicatorUnitA1A2A3A1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
HWDkg6.18e-13.28e-32.04e-26.42e-11.93e-21.75e-4000000008.70e-42.37e-31.16e-3-3.57e-2
NHWDkg8.13e+16.57e-26.31e+08.77e+14.07e-14.99e-2000000001.84e-26.41e-21.31e+1-2.29e+0
RWDkg2.50e-46.61e-74.17e-62.55e-44.40e-62.66e-9000000001.98e-73.83e-71.62e-7-3.76e-6
CRUkg000000000000000000
MFRkg000006.30e-30000000001.16e-100
MERkg000000000000000000
EEEMJ000003.20e-2000000000000
EETMJ000006.21e-2000000000000

ND = not declared. Life cycle modules: A1-A3 product stage, A4-A5 construction process, B use stage, C end of life, D benefits and loads beyond the system boundary.

Material composition

Product composition
Material/Component CategoryOrigin% Mass
PE-Xa Pipe0 - 60 %
HDPE Pipe20 - 90 %
PE-Xa Insulation5 - 25 %
Tape< 1 %
Brass Couplings1 - 10 %
Packaging
Packaging materialOriginMass (kg)
LDPE Film0.008
LDPE Caps and Plugs0.009
PET Straps0.005

Hazardous substances

No regulated hazardous or dangerous substances are included in this product.

Scenarios

Transport to the building site (A4)

Vehicle type
Lorry, Barge
Transport distance
1580 km
Capacity utilization
35%
Packaging mass
0.022 kg

End of life (C1-C4)

Collected with mixed construction waste
2.752 kg
Recycling
0.116 kg
Landfill
0.003 kg
Incineration
0.003 kg
Incineration with energy recovery
2.63 kg

Benefits and loads beyond the system boundary (D)

Recycling rate of product
4.2%
Recycled content of product
3.5%
Net energy benefit from energy recovery in C3, declared as exported energy
38.4 MJ

Product description

Watts Microflex® is a pre-insulated flexible pipe system for underground installation and the transport of fluids in cooling and heating systems (-10/+95°C) and domestic water. Ideal for residential systems and large district heating systems, Microflex® is suitable for hot and cold fluids, drinking water and other fluids for industrial systems. Supplied in 100 m coils or made to measure, thanks to its light weight, flexibility and ease of installation, it allows you to overcome obstacles without joints, reducing excavation time and costs.

Microflex’s pre-insulated piping system is composed of a thermal insulation around a carrier pipe and covered by a “closed chamber“ protective UV-resistant outer casing. Brass couplings are used to connect the carrier pipe to the rest of the plumbing network.

Watts sells Microflex® products covering a large range of sizes and applications. The carrier pipe for sanitary, HVAC and drinking water products are respectively made from cross-linked polyethylene (known as PE-Xa), from PE-Xa with an Ethylene Vinyl Alcohol (EVOH) membrane which acts as an oxygen diffusion barrier, or from PE100 polyethylene. Watts also offers a special Microflex® HP which includes corrugated PE conduit for hooking up power and network cables in heat pump applications.

Interpretation

The majority of life cycle impacts arise from raw material supply (A1) across most impact categories. Manufacturing (A3), distribution (A4), and end-of-life treatment (C4) each contribute up to approximately 20% in certain categories. Module D indicates potential offsets of life cycle impacts through material and energy substitution.

LCIA results are relative expressions and do not predict impacts on category endpoints, the exceeding of thresholds, safety margins or risks. EPDs are comparable only when they follow the same PCR, functional unit and system boundary. The full EPD (PDF) contains the methodology, scenario assumptions and verification statement.