Smart EPD
SuperLite® II-XL

Environmental Product Declaration

SuperLite® II-XL

by SAFTI FIRST® - Safti And Fire Technology Inc

Environmental Product Declaration (EPD) for SuperLite® II-XL, manufactured by SAFTI FIRST® - Safti And Fire Technology Inc. Declaration SmartEPD-2026-138-0927-01, prepared according to Smart EPD® Part A Product Category Rules for Building and Construction Products and Services, 1000, v1.2, valid until June 15, 2031.

Download the EPD (PDF)

Declared unit
1 m2 of product
Valid until
June 15, 2031
PCR
Smart EPD® Part A Product Category Rules for Building and Construction Products and Services, 1000, v1.2

Declaration details

Manufacturer
SAFTI FIRST® - Safti And Fire Technology Inc
Program operator
Smart EPD
Declaration number
SmartEPD-2026-138-0927-01
Date of issue
June 15, 2026
Valid until
June 15, 2031
Product category rules (PCR)
Smart EPD® Part A Product Category Rules for Building and Construction Products and Services, 1000, v1.2 (version 1.2)
Standard
ISO 14025:2006 and ISO 21930:2017
Declared unit
1 m2 of product
System boundary
Cradle to gate (A1 - A3)
Product specificity
Product Average
Manufacturing specificity
Facility Specific
Manufacturing plant
Merced, CA (220 S R St, Merced, CA 95341, USA)
Product SKU
SuperLite® II-XL provides maximum fire and impact safety with hose stream and provides full radiant heat protection.
Verifier
Anni Oviir, LCA Support
LCA software
SimaPro 10.2
Program instructions
Smart EPD General Program Instructions v.2.0, March 2025

Life cycle assessment results

Results per 1 m2 of product.

Environmental Impact Assessment Results

IndicatorUnitA1A2A3A1-A3
GWP-totalkg CO2 eq9.42e+14.46e+04.85e+11.47e+2
GWP-fossilkg CO2 eq9.13e+14.46e+04.85e+11.44e+2
GWP-biogenickg CO2 eq5.05e-11.01e-33.30e-25.39e-1
GWP-luluckg CO2 eq8.25e-22.34e-32.50e-21.10e-1
ODPkg CFC 11 eq1.01e-67.03e-83.02e-71.39e-6
APkg SO2 eq4.90e-12.32e-21.02e-16.15e-1
EP-marinekg N eq3.86e-26.30e-31.70e-26.20e-2
POCPkg O3 eq3.78e+07.47e-11.73e+06.26e+0

Resource Use Indicators

IndicatorUnitA1A2A3A1-A3
RPREMJ9.31e+18.24e-15.52e+26.46e+2
RPRMMJ0000
RPRTMJ9.31e+18.24e-15.52e+26.46e+2
NRPREMJ2.26e+36.21e+17.38e+23.06e+3
NRPRMMJ1.31e+2001.31e+2
NRPRTMJ2.39e+36.21e+17.38e+23.19e+3
ADP-fossilMJ1.35e+37.18e+16.26e+22.05e+3
SMkg0000
RSFMJ0000
NRSFMJ0000
FWm38.28e-11.00e-23.58e-11.20e+0
REMJ0000

Waste and Output Flow Indicators

IndicatorUnitA1A2A3A1-A3
HWDkg0000
NHWDkg001.80e+11.80e+1
HLRWkg0000
ILLRWkg0000
CRUkg0000
MFRkg0000
MERkg0000
EEEMJ0000

Carbon Emissions and Removals

IndicatorUnitA1A2A3A1-A3
BCRPkg CO20000
BCEPkg CO20000
BCRKkg CO200-3.25e+1-3.25e+1
BCEKkg CO2003.25e+13.25e+1

ND = not declared. Life cycle modules: A1-A3 product stage, A4-A5 construction process, B use stage, C end of life, D benefits and loads beyond the system boundary.

Material composition

Product composition
Material/Component CategoryOrigin% Mass
GlassUnited States64%
SRILUnited States27%
PolysulfideUnited States6%
OthersUnites States3%
Packaging
Packaging materialOriginMass (kg)
WoodUnited States14.2
FiberboardUnited States3.51
OthersUnited States0.37
Biogenic carbon
Biogenic carbon contentkg C per m2
Biogenic carbon content in product0
Biogenic carbon content in accompanying packaging8.85

Hazardous substances

None

Product description

SuperLite® II-XL is a fire resistive glazing product designed for maximum fire and impact safety. It is tint-free and optically clear, making it suitable for applications where maximum transparency and fire protection is required. The glazing is fully tested and approved for various applications, including full-vision temperature-rise doors and wall applications, and can be customized for additional safety features such as bullet resistance, blast resistance, forced entry, and hurricane protection. It is available in custom architectural make-ups and is proudly manufactured in the USA for competitive pricing and fast lead times.

Interpretation

The analysis of SAFTI FIRST fire resistive glass provides useful insights regarding the life cycle environmental impacts. The LCA results also identify where substantial impacts are occurring to allow further process and materials improvements to be implemented by SAFTI FIRST.

The raw materials module (A1) contributes the most to each impact category for the product, and the manufacturing module (A3) is the next largest contributor for each impact category.

For raw materials module (A1), the flat glass is the largest single contributor to most every impact category with the exception of GWP 100-luluc where Polysulfide is a slightly larger contributor.

Within the manufacturing module (A3), impacts associated with electricity consumption were the largest driver for all impacts with the exception of GWP 100-luluc where it was driven by wood packaging.

LCIA results are relative expressions and do not predict impacts on category endpoints, the exceeding of thresholds, safety margins or risks. EPDs are comparable only when they follow the same PCR, functional unit and system boundary. The full EPD (PDF) contains the methodology, scenario assumptions and verification statement.