Environmental Product Declaration
GlasRoc Sheathing 5/8” Gypsum Board - Seattle
Environmental Product Declaration (EPD) for GlasRoc Sheathing 5/8” Gypsum Board - Seattle, manufactured by CertainTeed Saint-Gobain. Declaration SmartEPD-2025-071-0526-02, prepared according to Smart EPD® Part B PCR for Gypsum Panels, 1000-004, v2.0, valid until December 16, 2030.
- Functional unit
- 1,000 ft2 of product
- Valid until
- December 16, 2030
- PCR
- Part B PCR for Gypsum Panels 1000-004
Declaration details
- Manufacturer
- CertainTeed Saint-Gobain
- Program operator
- Smart EPD
- Declaration number
- SmartEPD-2025-071-0526-02
- Date of issue
- December 16, 2025
- Valid until
- December 16, 2030
- Product category rules (PCR)
- Smart EPD® Part B PCR for Gypsum Panels, 1000-004, v2.0 (version 2)
- Standard
- ISO 14025:2006 and ISO 21930:2017
- Functional unit
- 1,000 ft2 of product
- System boundary
- Cradle to grave (A1 - A3, A4, A5, B1 - B7, C1 - C4)
- Product specificity
- Product Specific
- Manufacturing specificity
- Facility Specific
- Manufacturing plant
- CertainTeed Gypsum (5931 E Marginal Wy S, Seattle, WA 98134, USA)
- Product category
- Finishes › Gypsum
- Product SKU
- N/A
- Verifier
- Anna Lasso, Smart EPD
- LCA software
- Sphera LCA for Experts (formerly GaBi) 10.7.1
- Program instructions
- Smart EPD General Program Instructions v.1.0, November 2022
Life cycle assessment results
Results per 1,000 ft2 of product.
Environmental Impact Assessment Results
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GWP-total (excl biogenic) | kg CO2 eq | 3.54e+2 | 5.66e+1 | 6.10e+1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1.36e+1 | 0 | 2.43e+1 |
| GWP-total (incl biogenic) | kg CO2 eq | 3.54e+2 | 5.66e+1 | 2.30e+1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1.36e+1 | 0 | 2.42e+1 |
| GWP-total | kg CO2 eq | 3.39e+2 | 5.53e+1 | 2.04e+1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1.33e+1 | 0 | 2.31e+1 |
| GWP-total (excl biogenic) | kg CO2 eq | 3.39e+2 | 5.53e+1 | 5.84e+1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1.33e+1 | 0 | 2.32e+1 |
| ODP | kg CFC 11 eq | 1.23e-4 | 1.65e-13 | 4.26e-7 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 3.97e-14 | 0 | 1.14e-12 |
| AP | kg SO2 eq | 2.55e-1 | 1.77e-1 | 3.23e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 4.08e-2 | 0 | 1.23e-1 |
| EP-freshwater | kg N eq | 6.51e-2 | 1.78e-2 | 3.73e-2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 4.17e-3 | 0 | 5.29e-3 |
| EP-marine | kg N eq | 1.28e-1 | 1.63e-1 | 1.02e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 3.75e-2 | 0 | 6.20e-2 |
| POCP | kg O3 eq | 4.85e+0 | 4.76e+0 | 3.48e+0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 9.24e-1 | 0 | 2.20e+0 |
| ADP-fossil | MJ | 4.10e+3 | 7.35e+2 | 1.24e+3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1.76e+2 | 0 | 3.49e+2 |
| GWP-biogenic | kg CO2 eq | 3.94e-1 | 2.12e-2 | 1.04e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 5.09e-3 | 0 | 4.16e-2 |
| GWP-luluc | kg CO2 eq | 2.87e-1 | 3.00e-2 | 2.59e-2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 7.21e-3 | 0 | 1.60e-2 |
Resource Use Indicators
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PERE | MJ | 2.74e+2 | 3.28e+1 | 3.27e+2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 7.87e+0 | 0 | 4.46e+1 |
| PERM | MJ | 2.34e-2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| PERT | MJ | 2.74e+2 | 3.28e+1 | 3.27e+2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 7.87e+0 | 0 | 4.46e+1 |
| PENRE | MJ | 4.34e+3 | 7.41e+2 | 1.29e+3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1.78e+2 | 0 | 3.60e+2 |
| PENRM | MJ | 3.13e+1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| PENRT | MJ | 4.37e+3 | 7.41e+2 | 1.29e+3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1.78e+2 | 0 | 3.60e+2 |
| ADP-fossil | MJ | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| SM | kg | ND | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| RSF | MJ | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| NRSF | MJ | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| FW | m3 | 1.88e+0 | 1.09e-1 | 1.34e+0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 2.61e-2 | 0 | 4.65e-2 |
| RE | MJ | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
Waste and Output Flow Indicators
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| HWD | kg | 8.45e-4 | 9.99e-8 | 5.48e-7 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 2.40e-8 | 0 | 8.88e-8 |
| NHWD | kg | 9.19e+0 | 7.39e-2 | 1.44e+2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1.77e-2 | 0 | 1.10e+3 |
| RWD | kg | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| HLRW | kg | 1.38e-5 | 2.65e-6 | 1.23e-5 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 6.36e-7 | 0 | 4.28e-6 |
| ILLRW | kg | 1.24e-2 | 2.23e-3 | 1.14e-2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 5.36e-4 | 0 | 3.82e-3 |
| CRU | kg | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| MFR | kg | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| MER | kg | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| MNER | kg | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| EEE | MJ | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| EET | MJ | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
Carbon Emissions and Removals
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BCRP | kg CO2 | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| BCEP | kg CO2 | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| BCRK | kg CO2 | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| BCEK | kg CO2 | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| BCEW | kg CO2 | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| CCE | kg CO2 | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| CCR | kg CO2 | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
| CWNR | kg CO2 | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
ND = not declared. Life cycle modules: A1-A3 product stage, A4-A5 construction process, B use stage, C end of life, D benefits and loads beyond the system boundary.
Material composition
| Material/Component Category | Origin | % Mass |
|---|---|---|
| Gypsum | Undisclosed | 85 - 95 |
| Internally Recycled Gypsum | Undisclosed | 2 - 9 |
| Paper | Undisclosed | 2 - 6 |
| Fiberglass | Undisclosed | 0 - 1 |
| Silicone | Undisclosed | 0 - 1 |
| Additives | Undisclosed | 0 - 1 |
| Packaging material | Origin | Mass (kg) |
|---|---|---|
| Polyethylene low density granulate | Undisclosed | 0.05 |
| Spacer (Rejected gypsum board) | Undisclosed | 0.9 |
| Polyethylene high density granulate | Undisclosed | 0.05 |
Hazardous substances
No regulated hazardous or dangerous substances are included in this product.
Scenarios
Transport to the building site (A4)
- Fuel type
- Diesel
- Vehicle type
- Commercial tractor-trailer truck
- Transport distance
- 448 km
- Capacity utilization
- 70%
- Packaging mass
- 1.938 kg
Transport to the building site (A4)
- Fuel type
- Diesel
- Vehicle type
- Rail
- Transport distance
- 208 km
- Capacity utilization
- 70%
- Packaging mass
- 1.938 kg
Transport to the building site (A4)
- Fuel type
- Diesel
- Vehicle type
- Single unit truck
- Transport distance
- 40 km
- Capacity utilization
- 70%
- Packaging mass
- 1.938 kg
End of life (C1-C4)
- Collected with mixed construction waste
- 1098 kg
- Product or material for final disposal
- 1098 kg
Product description
CertainTeed's GlasRoc Sheathing is a high-performance, non-combustible gypsum-based sheathing that offers exceptional fire resistance, moisture resistance, and mold resistance for exterior wall and soffit systems. Made from a combination of gypsum core and fiberglass mat facers, the product is engineered to withstand the elements and provide long-lasting performance.
GlasRoc Sheathing is designed to be used in exterior wall applications, providing a strong and durable surface for finishing materials such as stucco, brick, and siding. The sheathing is lightweight and easy to handle, making it easy to transport and install. It is also available in a variety of sizes and thicknesses to meet the specific needs of any construction or renovation project. The product is designed to provide exceptional moisture resistance, which is essential for protecting the integrity of the building envelope. The fiberglass mat facing on the sheathing provides a barrier against moisture infiltration, helping to prevent damage to the framing and insulation. This feature also helps to improve indoor air quality by preventing the growth of mold and mildew.
Interpretation
Based on the results from the life cycle assessment model, the life cycle impacts are strongly driven by the manufacture. The impacts of the manufacture are primarily attributed to the natural gas usage needed for the ovens to dry the boards. The natural gas usage in the manufacture accounts for as much as 43% of the cradle-to-grave environmental impact potentials for CertainTeed GlasRoc Sheathing 5/8” Gypsum Boards at the Seattle, WA facility.
The manufacturing of gypsum board (A3) has the highest contribution to Global Warming Potential impacts. The use of internally recycled gypsum material helps to reduce the overall environmental impact potentials by reducing the amount of external raw materials needed for the process.
Another potentially significant contributor to the overall environmental impact results is seen in the results for the installation of the Gypsum Boards. The installation waste accounts for the majority of the impacts for installation. The PCR requires the use of a 10% installation waste scenario in the absence of actual data. As there is currently no actual installation data available, and because installation techniques may vary widely among installers, CertainTeed has little to no influence on the installation impacts.
LCIA results are relative expressions and do not predict impacts on category endpoints, the exceeding of thresholds, safety margins or risks. EPDs are comparable only when they follow the same PCR, functional unit and system boundary. The full EPD (PDF) contains the methodology, scenario assumptions and verification statement.