Environmental Product Declaration
GacoFlex S2000 Solvent-Free 100% Silicone Coating
by Gaco
Environmental Product Declaration (EPD) for GacoFlex S2000 Solvent-Free 100% Silicone Coating, manufactured by Gaco. Declaration SmartEPD-2025-099-0673-01, prepared according to NSF Product Category Rules for Roof Coatings: NAICS 324122 & 325510, valid until December 10, 2030.
- Functional unit
- 1 m2 of product
- Valid until
- December 10, 2030
- PCR
- NSF Product Category Rules for Roof Coatings: NAICS 324122 & 325510
Declaration details
- Manufacturer
- Gaco
- Program operator
- Smart EPD
- Declaration number
- SmartEPD-2025-099-0673-01
- Date of issue
- December 10, 2025
- Valid until
- December 10, 2030
- Product category rules (PCR)
- NSF Product Category Rules for Roof Coatings: NAICS 324122 & 325510 (version 2, extension 3)
- Standard
- ISO 14025:2006 and ISO 21930:2017
- Functional unit
- 1 m2 of product
- System boundary
- Cradle to grave (A1 - A3, A4, A5, B1 - B7, C1 - C4)
- Product specificity
- Product Specific
- Manufacturing specificity
- Facility Specific
- Manufacturing plant
- Waukesha Wisconsin (1245 Chapman Dr, Waukesha, WI 53186, USA)
- Product category
- ThermalMoistureProtection › DampproofingAndWaterproofing
- Product service life
- 20 years
- Verifier
- Lucas Pedro Berman, Senda - Consultoria Ambiental & Energetica
- LCA software
- Emidat 1.0
- Program instructions
- Smart EPD General Program Instructions v.2.0, March 2025
Life cycle assessment results
Results per 1 m2 of product.
Environmental Impact Assessment Results
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GWP-total | kg CO2 eq | 2.10e+0 | 9.25e-2 | 1.95e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1.93e-2 | 1.68e+0 | 0 |
| ODP | kg CFC 11 eq | 7.69e-7 | 1.59e-9 | 3.89e-8 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 3.07e-10 | 7.97e-9 | 0 |
| AP | kg SO2 eq | 9.07e-3 | 2.07e-4 | 5.08e-4 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 8.11e-5 | 8.71e-4 | 0 |
| EP | kg N eq | 1.97e-2 | 9.62e-5 | 1.12e-3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 3.26e-5 | 2.60e-3 | 0 |
| SFP | kg O3 eq | 1.28e-1 | 4.42e-3 | 7.52e-3 | 8.04e-2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 2.02e-3 | 1.79e-2 | 0 |
Resource Use Indicators
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PERE | MJ, net calorific value | 2.75e+0 | 1.85e-2 | 1.43e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 6.96e-3 | 9.70e-2 | 0 |
| PERM | MJ, net calorific value | 1.51e-4 | 0 | -1.44e-4 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| PERT | MJ, net calorific value | 2.75e+0 | 1.85e-2 | 1.43e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 6.96e-3 | 9.70e-2 | 0 |
| PENRE | MJ, net calorific value | 2.65e+1 | 1.41e+0 | 1.53e+0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 2.69e-1 | 2.55e+0 | 0 |
| PENRM | MJ, net calorific value | 5.29e+0 | 0 | 2.43e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | -4.95e+0 | 0 |
| PENRT | MJ, net calorific value | 3.18e+1 | 1.41e+0 | 1.77e+0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 2.69e-1 | -2.40e+0 | 0 |
| SM | kg | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| RSF | MJ, net calorific value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| NRSF | MJ, net calorific value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| RE | MJ | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| FW | m3 | 5.36e-2 | 2.08e-4 | 2.77e-3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 4.60e-5 | 1.61e-3 | 0 |
Waste and Output Flow Indicators
| Indicator | Unit | A1-A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| HWD | kg | 1.35e-2 | 0 | 4.27e-2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 8.40e-1 | 0 |
| NHWD | kg | 2.03e-2 | 0 | 1.58e-3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| RWD | kg | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| CRU | kg | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| MFR | kg | 3.79e-3 | 0 | 1.95e-4 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| MER | kg | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| EE | MJ | 2.48e-1 | 0 | 7.92e-1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1.54e+1 | 0 |
ND = not declared. Life cycle modules: A1-A3 product stage, A4-A5 construction process, B use stage, C end of life, D benefits and loads beyond the system boundary.
Material composition
| Material/Component Category | Origin | % Mass |
|---|---|---|
| Additives | Various | 0-2 |
| Fillers | USA | 25-50 |
| Pigments | USA | 2-10 |
| Resins | Various | 50-80 |
| Packaging material | Origin | Mass (kg) |
|---|---|---|
| Cardboard | 1.19e-05 | |
| Steel | 5.86e-05 | |
| Plastic film | 5.10e-06 | |
| HDPE | 4.96e-04 |
| Biogenic carbon content | kg C per m2 |
|---|---|
| Biogenic carbon content in product | 0 |
| Biogenic carbon content in accompanying packaging | 0.0000055 |
Hazardous substances
No regulated hazardous or dangerous substances are included in this product.
Scenarios
Transport to the building site (A4)
- Vehicle type
- transport, freight, lorry >32 metric ton, EURO6
- Transport distance
- 1074 km
- Capacity utilization
- 53.30%
- Weight of products transported
- 0.84 kg
End of life (C1-C4)
- Incineration
- 0.84 kg
- Product or material for final disposal
- 0.84 kg
Product description
GacoFlex S2000 White is a solvent-free, single-component waterproof elastomeric moisture-curing silicone roof coating. S2000 may be used as maintenance coating systems over existing elastomeric roof coatings, metal roofs, built-up roofing, mineral cap sheets, modified bitumen (APP and SBS) and weathered single ply membranes (EPDM, PVC, CSPE, and TPO/CPA) where the membrane is in sound condition but requires a renewal of the membrane surface due to the normal effects of aging and use. S2000 is ideal for use over sprayed-in-place polyurethane foam roofing such as GacoRoofFoam, concrete, plywood decking and on roof surfaces that are used as part of rainwater catchment systems. When properly applied, S2000 provides a seamless weather-tight seal that protects the substrate from degradation caused by ultraviolet light, water and other normal weathering hazards.
Application involves cleaning and preparing the roof surface, then applying the coating using rollers, brushes, or sprayers in one or more layers. Once cured, the coating forms a flexible, weather-resistant membrane that adheres tightly to the substrate.
Interpretation
Based on the results and study assumptions, methods, and data, the cradle-to-gate impacts (A1–A3) for the product represent approximately 50% of the total Global Warming Potential (GWP). The remaining impacts occur in later life-cycle stages.
LCIA results are relative expressions and do not predict impacts on category endpoints, the exceeding of thresholds, safety margins or risks. EPDs are comparable only when they follow the same PCR, functional unit and system boundary. The full EPD (PDF) contains the methodology, scenario assumptions and verification statement.