Smart EPD
DuraFlex Non-Insulated Door

Environmental Product Declaration

DuraFlex Non-Insulated Door

by DuraFlex

Environmental Product Declaration (EPD) for DuraFlex Non-Insulated Door, manufactured by DuraFlex. Declaration SmartEPD-2025-053-0278-01, prepared according to Smart EPD® Part A Product Category Rules for Building and Construction Products and Services v1.01, valid until January 22, 2030.

Download the EPD (PDF)

Functional unit
1 piece of product allowing passage, with the dimensions 9×10 ft
Valid until
January 22, 2030
PCR
Smart EPD Part A v1.01

Declaration details

Manufacturer
DuraFlex
Program operator
Smart EPD
Declaration number
SmartEPD-2025-053-0278-01
Date of issue
January 22, 2025
Valid until
January 22, 2030
Product category rules (PCR)
Smart EPD® Part A Product Category Rules for Building and Construction Products and Services v1.01 (version 1.01)
Standard
ISO 14025:2006 and ISO 21930:2017
Functional unit
1 piece of product allowing passage, with the dimensions 9×10 ft
System boundary
Cradle to gate with other options (A1 - A3, C1 - C4)
Product specificity
Product Specific
Manufacturing specificity
Facility Specific
Manufacturing plant
DuraFlex (899 Venture Blvd, Wooster, OH, USA)
Product category
Openings › DoorsAndFrames
Product SKU
DuraFlex Non-Insulated Sectional Door (110WX120H-VL-DFN)
Verifier
Alison Conroy, Independent Contractor
LCA software
SimaPro 9.6
Program instructions
Smart EPD General Program Instructions v.1.0, November 2022

Life cycle assessment results

Results per 1 piece of product allowing passage, with the dimensions 9×10 ft.

Environmental Impact Assessment Results

IndicatorUnitA1A2A3A1-A3C1C2C3C4
GWP-totalkg CO2 eq1.20e+34.35e+18.45e+11.33e+304.75e+002.78e+0
ODPkg CFC 11 eq1.83e-56.24e-71.92e-62.09e-507.25e-802.12e-8
APkg SO2 eq4.76e+04.48e-11.21e-15.33e+002.45e-209.16e-3
EPkg N eq3.45e+05.62e-24.30e-13.94e+005.26e-301.15e+0
POCPkg O3 eq5.53e+11.09e+12.57e+06.88e+106.92e-101.33e-1
GWP-luluckg CO2 eq1.89e+02.02e-23.08e-21.94e+001.87e-307.76e-4

Resource Use Indicators

IndicatorUnitA1A2A3A1-A3C1C2C3C4
PEREMJNDNDNDNDNDNDNDND
PERMMJNDNDNDNDNDNDNDND
PERTMJNDNDNDNDNDNDNDND
PENREMJNDNDNDNDNDNDNDND
PENRMMJNDNDNDNDNDNDNDND
PENRTMJNDNDNDNDNDNDNDND
RPREMJ1.10e+39.20e+02.93e+21.40e+308.40e-105.32e-1
RPRMMJ2.32e+2002.32e+20000
RPRTMJ2.32e+27.03e+02.93e+25.33e+201.04e+008.73e-1
NRPREMJ1.52e+45.72e+21.38e+31.72e+406.71e+101.77e+1
NRPRMMJ1.93e+1001.93e+10000
NRPRTMJ1.52e+45.72e+21.38e+31.72e+406.71e+101.77e+1
ADP-fossilMJ1.15e+37.47e+11.95e+21.42e+308.87e+002.14e+0
SMkg1.25e+1001.25e+10000
RSFMJ00000000
NRSFMJ00000000
FWm31.03e+18.07e-21.37e-11.05e+108.90e-30-2.07e-1

Waste and Output Flow Indicators

IndicatorUnitA1A2A3A1-A3C1C2C3C4
HWDkg00000000
NHWDkg001.76e+11.76e+10006.50e+1
RWDkgNDNDNDNDNDNDNDND
HLRWkgNDNDNDNDNDNDNDND
ILLRWkgNDNDNDNDNDNDNDND
CRUkgNDNDNDNDNDNDNDND
MFRkg007.51e+07.51e+00001.83e+2
MERkg006.30e-16.30e-10007.91e-1
MNERkgNDNDNDNDNDNDNDND
EEEMJNDNDNDNDNDNDNDND
EETMJNDNDNDNDNDNDNDND

Carbon Emissions and Removals

IndicatorUnitA1A2A3A1-A3C1C2C3C4
BCRPkg CO21.19e+0001.19e+00000
BCEPkg CO200000007.15e-3
BCRKkg CO2002.74e+12.74e+10000
BCEKkg CO200000001.64e-1
BCEWkg CO2NDNDNDNDNDNDNDND
CCEkg CO2NDNDNDNDNDNDNDND
CCRkg CO2NDNDNDNDNDNDNDND
CWNRkg CO2NDNDNDNDNDNDNDND

ND = not declared. Life cycle modules: A1-A3 product stage, A4-A5 construction process, B use stage, C end of life, D benefits and loads beyond the system boundary.

Material composition

Product composition
Material/Component CategoryOrigin% Mass
SteelUS56.6
SteelTaiwan19.7
PlasticUS0.8
PlasticTaiwan6.6
ThermosetUS11.9
AluminumUS1.2
OtherUS3.3
Packaging
Packaging materialOriginMass (kg)
CardboardUS2.6
Pallet12.4

Hazardous substances

No regulated hazardous or dangerous substances are included in this product.

Product description

DuraFlex Non-Insulated Sectional Doors

DuraFlex is the long-term solution for businesses who can’t afford to stop moving. Our flexible, high-strength doors were born as a solution to an all-too-common problem our customers faced. The time and money lost to an inoperable door was stacking up, and our trusted partners needed a sustainable solution.

With our customers’ problem in mind, we set out to design a door that could stand the test of time in any work environment. At the end, we had created the new industry standard in durable overhead doors.

Engineering design is the key to our door’s longevity. Our panels are constructed from a composite material that gives upon impact, but always flexes back into place. In a warehouse environment, a DuraFlex door can take the bumps and bruises that come with the territory. Add on industry-strength hardware, 3” tracks, and springs with a minimum of 10,000 cycles, and you have a commercial overhead door that is designed to keep your business moving.

DuraFlex Non-Insulated Impactable Sectional Overhead Door using a smooth flush exterior skin. Track Design is Continuous Clip Mount Angle for Steel and Masonry. Panel substrate is 3MM thick composite sheet constructed using HDPE core and galvanized steel for the exterior skin. Door Operation: manual, chain hoist or electric operators.

Interpretation

Interpretation is the last phase of an LCA, although it is typically done iteratively to inform and refine the goal and scope. In this section, the results are examined based on the data quality and consistency. Key assumptions are reviewed to ensure that conclusions and recommendations are consistent with the goal and scope. It should be noted that LCA results are based on a relative approach and indicate potential environmental effects therefore do not predict actual impacts on category end points.

Based on the results and study assumptions, methods and data, the cradle-to-gate impacts for, the contribution analysis indicates that the majority of the potential impacts occur as a result of raw material supply (A1), specifically steel, high density polyethylene and aluminum.

LCIA results are relative expressions and do not predict impacts on category endpoints, the exceeding of thresholds, safety margins or risks. EPDs are comparable only when they follow the same PCR, functional unit and system boundary. The full EPD (PDF) contains the methodology, scenario assumptions and verification statement.