Smart EPD
BP ESGARD Roof Insulation: High Resistance

Environmental Product Declaration

BP ESGARD Roof Insulation: High Resistance

by BP Canada

Environmental Product Declaration (EPD) for BP ESGARD Roof Insulation: High Resistance, manufactured by BP Canada. Declaration SmartEPD-2025-080-0584-01.2, prepared according to UL Part B: Building Envelope Thermal Insulation Products, valid until September 8, 2030.

Download the EPD (PDF)

Functional unit
1 m2 of product
Valid until
September 8, 2030
PCR
UL Part B: Building Envelope Thermal Insulation Products

Declaration details

Manufacturer
BP Canada
Program operator
Smart EPD
Declaration number
SmartEPD-2025-080-0584-01.2
Date of issue
September 8, 2025
Valid until
September 8, 2030
Product category rules (PCR)
UL Part B: Building Envelope Thermal Insulation Products (version 3)
Standard
ISO 14025:2006 and ISO 21930:2017
Functional unit
1 m2 of product
System boundary
Cradle to gate with other options (A1 - A3, A4, A5, B4, C1 - C4)
Product specificity
Product Specific
Manufacturing specificity
Facility Specific
Manufacturing plant
BP Canada (420 Dupont Street, Pont-Rouge, Québec G3H 1S2, Canada)
Product category
ThermalMoistureProtection › Insulation
Product SKU
BRC05*, BRN05*,BRC10*, BRN10*, BRI10
Product service life
75 years
Verifier
Vijay Thakur, Individual Verifier
LCA software
Sphera LCA for Experts (formerly GaBi) 10.9
Program instructions
Smart EPD General Program Instructions v.2.0, March 2025

Life cycle assessment results

Results per 1 m2 of product.

Environmental Impact Assessment Results

IndicatorUnitA1A2A3A1-A3A4A5B4C1C2C3C4
GWP-totalkg CO2 eq-1.57e+13.71e-16.52e+0-8.81e+02.97e-14.07e-1-2.31e+003.15e-202.14e+1
GWP-fossilkg CO2 eq1.11e+03.71e-16.56e+08.04e+02.97e-13.72e-11.20e+103.15e-204.63e+0
ODPkg CFC 11 eq8.87e-91.39e-113.55e-84.44e-81.11e-115.85e-124.00e-801.18e-1201.02e-14
APkg SO2 eq5.93e-32.80e-34.24e-31.30e-21.76e-32.69e-33.52e-201.87e-402.15e-2
EPkg N eq3.86e-31.60e-45.41e-44.56e-39.74e-54.19e-41.15e-201.04e-507.68e-3
POCPkg O3 eq1.64e-36.21e-52.57e-41.96e-34.47e-54.84e-52.13e-304.75e-603.11e-4
ADP-fossilMJ3.09e+06.48e-11.31e+11.68e+15.18e-13.57e-11.63e+105.50e-204.19e-1

Resource Use Indicators

IndicatorUnitA1A2A3A1-A3A4A5B4C1C2C3C4
RPREMJ1.08e+205.03e+11.58e+202.11e+01.45e+20004.01e-1
RPRMMJ1.61e+207.48e+12.36e+203.14e+02.16e+20005.95e-1
RPRTMJ2.69e+201.25e+23.94e+205.26e+03.61e+20009.96e-1
NRPREMJ2.70e+14.71e+08.92e+11.21e+23.77e+02.68e+01.18e+204.00e-103.23e+0
NRPRMMJ00000000000
NRPRTMJ2.70e+14.71e+08.92e+11.21e+23.77e+02.68e+01.18e+204.00e-103.23e+0
SMkg9.14e+0009.14e+0008.23e+00000
FWm35.11e-202.91e-13.42e-105.91e-33.14e-10009.00e-4

Waste and Output Flow Indicators

IndicatorUnitA1A2A3A1-A3A4A5B4C1C2C3C4
HWDkg2.19e-403.51e-82.19e-401.20e-91.97e-40007.98e-10
NHWDkg4.60e-204.24e-28.84e-203.44e-18.10e+00008.57e+0
RWDkg00000000000
HLRWkg2.07e-702.90e-74.97e-701.51e-84.96e-70003.84e-8
ILLRWkg1.68e-402.45e-44.13e-401.28e-54.14e-40003.43e-5
CRUkg00000000000
MFRkg0000000006.90e-10
MERkg00000000000
MNERkg00000000000
EEEMJ00000000000
EETMJ00000000000

Carbon Emissions and Removals

IndicatorUnitA1A2A3A1-A3A4A5B4C1C2C3C4
BCRPkg CO2-1.68e+100-1.68e+10000000
BCEPkg CO200000000001.68e+1
BCRKkg CO200-5.00e-2-5.00e-20000000
BCEKkg CO2000005.00e-200000
BCEWkg CO200000000000
CCEkg CO200000000000
CCRkg CO200000000000
CWNRkg CO200000000000

ND = not declared. Life cycle modules: A1-A3 product stage, A4-A5 construction process, B use stage, C end of life, D benefits and loads beyond the system boundary.

Material composition

Product composition
Material/Component CategoryOrigin% Mass
WoodConfidential85.00 – 95.00
AsphaltConfidential0.00 – 6.00
StarchConfidential1.00 – 3.00
WaxConfidential<1.00
AdditivesConfidential<1.00
Packaging
Packaging materialOriginMass (kg)
Plastic BagConfidential2.00E-02
StrappingConfidential3.06E-03
Wood PlankConfidential3.30E-02
Biogenic carbon
Biogenic carbon contentkg C per m2
Biogenic carbon content in product4.58
Biogenic carbon content in accompanying packaging0.014

Hazardous substances

No substances required to be reported as hazardous are associated with the production of this product

Scenarios

Transport to the building site (A4)

Fuel type
Diesel
Vehicle type
Diesel Pow-ered truck/Trailer
Transport distance
800 km
Capacity utilization
85%
Packaging mass
0.06 kg

End of life (C1-C4)

Collected with mixed construction waste
9.86 kg
Recycling
0.69 kg
Landfill
9.17 kg
Product or material for final disposal
9.86 kg

Product description

This Environmental Product Declaration covers BP ESGARD Roofing Insulation Panels, including High Resistance variants, natural, coated 1 side and coated 6 sides in 1/2 inch thicknesses. These panels are engineered wood fibre insulation products designed to improve roof durability, thermal performance, and water resistance. Both products are composed of interwoven or interlocking wood fibres treated with a water-repellent wax emulsion, enhancing resistance to water absorption. Panels are either natural, factory-coated on one side or on all sides for added protection and compatibility with roofing applications. BP ESGARD Roof Insulation Panels offer excellent insulating properties while increasing the rigidity and strength of roofing systems. They provide robust support for membranes and are ideal surfaces for the application of hot bitumen or asphalt. The High Strength panels offer enhanced transverse load resistance and compressive strength, meeting CAN ULC-S706 Type II Class 2 and ASTM C-208 Type II Grade 2 standards. These qualities make the panels suitable for demanding roofing environments requiring structural reinforcement and reliable thermal insulation.

Interpretation

To fully understand the results of the life cycle assessment, it is crucial to comprehensively review and ensure completeness, sensitivity, and consistency. The completeness check ensures that all relevant processes, inputs, and outputs are considered in the LCA. This study carefully examined key stages such as raw materials, raw material transportation, and manufacturing, and found no significant data gaps. The sensitivity check supported these findings by exploring the impacts of varying natural gas consumption by ±10%, showing that changes in natural gas usage could reduce environmental impacts. A consistency check was also performed to ensure that the assumptions, data sources, and methodologies used in the LCA were applied consistently and aligned with the study's goals. These checks validate the reliability of the LCA findings and emphasize the significant impact of manufacturing processes, energy efficiency, raw material selection, and end-of-life considerations on the overall environmental performance of the products studied

The results of the life cycle assessment indicate that replacement(B4), the manufacturing process(A3), end of life(C1-C4) and raw material(A1) phases have the most significant impacts on the environmental performance of the products under study. More than 60% of the overall global warming potential of each thickness is attributed to the manufacturing process. The majority of the manufacturing impacts are due to the use of natural gas, which contributes to 95% of the replacement(B4).

Improving energy efficiency at the manufacturing facility in Pont Rouge, QC would help to reduce the overall environmental impacts for all product groupings. Moreover, the sensitivity analysis of the natural gas impacts at ±10% of the current manufacturing model provides valuable insights into the influence of energy inputs on the environmental impact intensity of wood fiber panels production. The results indicate that reducing natural gas consumption by 10% could achieve a more significant decrease in overall environmental impact potentials. These findings underscore the importance of prioritizing natural gas efficiency improvements to achieve more substantial environmental benefits in wood fiber panels production.

LCIA results are relative expressions and do not predict impacts on category endpoints, the exceeding of thresholds, safety margins or risks. EPDs are comparable only when they follow the same PCR, functional unit and system boundary. The full EPD (PDF) contains the methodology, scenario assumptions and verification statement.