Smart EPD
Nullifire FB750

Environmental Product Declaration

Nullifire FB750

by Tremco CPG

Environmental Product Declaration (EPD) for Nullifire FB750, manufactured by Tremco CPG. Declaration SmartEPD-2024-026-0136-01, prepared according to EPD International PCR for Construction Products 2019:14 (EN 15804:A2:2019/AC:2021), valid until June 11, 2029.

Download the EPD (PDF)

Declared unit
1 m2 of product
Valid until
June 11, 2029
PCR
EPD International PCR for Construction Products

Declaration details

Manufacturer
Tremco CPG
Program operator
Smart EPD
Declaration number
SmartEPD-2024-026-0136-01
Date of issue
June 11, 2024
Valid until
June 11, 2029
Product category rules (PCR)
EPD International PCR for Construction Products 2019:14 (EN 15804:A2:2019/AC:2021) (version 1.3.2)
Standard
ISO 14025:2006 and EN 15804+A2:2019/AC:2021
Declared unit
1 m2 of product
System boundary
Cradle to gate with other options (A1 - A3, A4, A5, B1, C1 - C4, D)
Product specificity
Product Specific
Manufacturing specificity
Facility Specific
Manufacturing plant
Tremco - Wigan (Tremco Illbruck Coatings Ltd, Coupland Road, Hindley Green, Wigan, UK)
Product category
ThermalMoistureProtection › Insulation › BoardInsulation
Product SKU
FB750345146, FB750502465
Product service life
60 years
Verifier
Rifat Karim
LCA software
SimaPro 9.5
Program instructions
Smart EPD General Program Instructions v.1.0, November 2022

Life cycle assessment results

Results per 1 m2 of product.

Environmental Impact Assessment Results

IndicatorUnitA1-A3A4A5B1C1C2C3C4D
GWP-totalkg CO2 eq1.61e+12.10e-16.84e-1005.79e-205.06e+00
GWP- totalkg CO2 eq1.61e+12.10e-16.84e-1005.79e-205.06e+00
GWP- fossilkg CO2 eq1.66e+12.10e-19.66e-3005.78e-203.40e-10
GWP-biogenickg CO2 eq-5.19e-11.92e-46.75e-1005.29e-504.72e+00
GWP-luluckg CO2 eq1.50e-21.04e-43.89e-6002.85e-501.37e-40
ODPkg CFC11 eq4.07e-64.56e-96.34e-11001.26e-902.21e-90
APmol H+ eq1.12e-14.74e-43.05e-5001.26e-401.07e-30
PMdisease incidence7.97e-71.55e-83.94e-10004.29e-901.38e-80
IRPkBq U235 eq4.35e-11.51e-38.68e-5004.16e-403.06e-30
POCPkg NMVOC eq1.58e+17.23e-46.56e-59.27e-1101.96e-402.31e-30
EP-fwkg P eq2.02e-41.70e-69.47e-7004.69e-703.34e-50
EP-marinekg N eq1.07e-21.17e-42.25e-4003.11e-507.94e-30
EP-terrestrialmol N eq3.25e-11.22e-38.65e-5003.24e-403.04e-30
SQIdimensionless2.01e+11.80e+01.06e-1004.96e-103.74e+00
WDPm3 world eq deprived3.78e+01.23e-22.13e-3003.38e-307.50e-20
ADP-fossilMJ, net calorific value2.43e+22.98e+06.14e-2008.21e-102.15e+00
ADP-minerals&metalskg Sb eq3.91e-56.84e-71.12e-8001.89e-703.92e-70
ETP-fwioCTUe6.25e+11.42e+04.52e-1003.91e-101.59e+10
ETP-fwoCTUe1.42e+25.35e-22.68e-32.34e-1101.47e-209.44e-20
HTP-cioCTUh4.08e-94.66e-114.85e-12001.28e-1101.71e-100
HTP-coCTUh3.59e-84.90e-118.66e-135.57e-2201.35e-1103.03e-110
HTP-ncioCTUh1.52e-72.00e-97.93e-11005.51e-1002.79e-90
HTP-ncoCTUh9.91e-71.13e-101.81e-101.80e-1903.12e-1106.39e-90

Resource Use Indicators

IndicatorUnitA1-A3A4A5B1C1C2C3C4D
PEREMJ2.27e+14.68e-22.87e-3001.29e-201.01e-10
PERMMJ9.87e+000000000
PERTMJ3.26e+14.68e-22.87e-3001.29e-201.01e-10
PENREMJ2.34e+22.98e+06.14e-2008.21e-102.15e+00
PENRMMJ8.17e+01.49e-44.83e-6004.12e-501.70e-40
PENRTMJ2.42e+22.98e+06.14e-2008.21e-102.15e+00
SMkg2.27e+000000000
RSFMJ000000000
NRSFMJ000000000
REMJ000000000
FWm31.17e-13.67e-45.40e-5001.01e-401.90e+00

Waste and Output Flow Indicators

IndicatorUnitA1-A3A4A5B1C1C2C3C4D
HWDkg2.35e-37.45e-51.35e-4002.06e-504.76e-30
NHWDkg2.38e+01.48e-11.78e-1004.08e-206.28e+00
RWDkg4.61e-39.78e-75.49e-8002.70e-701.93e-60
CRUkg000000000
MFRkg000000000
MERkg000000000
EEEMJ000000000
EETMJ000000000

Carbon Emissions and Removals

IndicatorUnitA1-A3A4A5B1C1C2C3C4D
BCRPkg CO2000000000
BCEPkg CO2000000000
BCRKkg CO25.27e-100000000
BCEKkg CO2005.27e-1000000
BCEWkg CO2000000000

ND = not declared. Life cycle modules: A1-A3 product stage, A4-A5 construction process, B use stage, C end of life, D benefits and loads beyond the system boundary.

Material composition

Product composition
Material/Component CategoryOrigin% Mass
Mineral BoardRoW70-90
CoatingRoW10-30
Packaging
Packaging materialOriginMass (kg)
LDPE bagRER9.79E-02
Wood PalletRER3.47E-01
Pallet WrapRER1.45E-02
Biogenic carbon
Biogenic carbon contentkg C per m2
Biogenic carbon content in product0
Biogenic carbon content in accompanying packaging0.144

Hazardous substances

The product does not contain any substances from the Candidate List of Substances of Very High Concern (SVHC)f or authorisation in amounts greater than 0,1%(1000ppm).

Scenarios

Transport to the building site (A4)

Fuel type
Diesel
Vehicle type
Truck
Transport distance
813.4871272 km
Capacity utilization
36.67%
Weight of products transported
8.867 kg
Packaging mass
0.45964325 kg

End of life (C1-C4)

Collected with mixed construction waste
8.69 kg
Landfill
8.69 kg
Product or material for final disposal
8.69 kg

Benefits and loads beyond the system boundary (D)

Recycled content of product
22.7%

Product description

FB750 Intubatt is a lightweight fire barrier comprising of a rock mineral fibre board with an uniquely identifiable ablative coating, containing OptifireTM unique traceability identifier. FB750 is designed to reinstate the fire performance of compartment walls and floors which have been breached by penetrating services, providing a fire, smoke, thermal, acoustic and air pressure seal.

FB750 must be used in conjunction with FS702 Intumastic to be suitable for sealing around the following service types: non-combustible pipes, cable trays, ladders and baskets (perforated or non-perforated), armoured cables, data cables, HV cables, cable bundles up to 100 mm.

FB750 can be used on flexible walls & rigid walls (90 mm or wider), rigid floors (150 mm or wider), beneath raised access floors / suspended floors and ceiling voids, as a continuation of the fire compartment.

When used with a Nullifire closer device (FS709 HP, FP302 Intustrap, FP220 Service Sleeve, FP170 Intucollar), FB750 Intubatt also becomes suitable for penetrating combustible services & conduits such as PVC, PE, PP, HDPE, PPR, PEX, Uponor and combustible ducting.

FB750 has also been tested to fire protect the underside of loaded timber floors for up to 120 minutes (BS 476 Pt 21). Typical areas of use include: health and leisure facilities, schools, universities, commercial buildings, hospitals, retail and industrial units and nuclear power plants.

Interpretation

The module of raw material extraction and processing (A1) was the main driver of most environmental impacts and resource use indicators, with particular influence of the upstream manufacture of the uncoated mineral wool batt. Manufacturing related impacts (A3) are important with regard to water depletion and toxicity impact categories. This means, for example, that interventions regarding the sustainable procurement of raw materials, in particular the procurement of the uncoated batt, will have the most impact regarding climate change and non-renewable energy consumption indicators. On the other hand, significant improvements on toxicity impacts can be better achieved by intervention on the manufacturing process itself. Finally, the end-of-life phase has also a noticeable influence on climate change, eutrophication, and ecotoxicity indicators.

LCIA results are relative expressions and do not predict impacts on category endpoints, the exceeding of thresholds, safety margins or risks. EPDs are comparable only when they follow the same PCR, functional unit and system boundary. The full EPD (PDF) contains the methodology, scenario assumptions and verification statement.